background image

Rense

ignements add

itionne

ls

 

Mode de

 d

égivr

age

 - 

Pour a

ssure

r un fonct

ionneme

nt fia

ble par t

emps fro

id, le VRC 

pas

se  

  

auto

matique

ment 

à so

n mode d

e d

égivra

ge lorsque

 la t

empéra

ture

 des

cend 

au-

dessous

 du p

oint d

congél

ation,

 afi

n d'é

vite

r une a

ccumulation 

de g

ivre

VR

C

 - 

Le ve

ntilate

ur à ré

cupération 

de chale

ur (

VRC) es

t c

onçu po

ur fo

urnir d

e l'

air ne

uf d

ans

 un 

édifice

, t

out en é

vacua

nt un

e q

uantit

é éga

le d'

air vicié

. Dura

nt le

s mois d

'hiver, 

l'air ne

uf et 

froid qui 

arriv

e es

t récha

uffé

 au mo

yen d

e la

 cha

leur r

écupéré

e d

e l'

air vicié

 ava

nt son 

expuls

ion ve

rs    

l'ext

érie

ur. Pe

ndant 

les m

ois d'é

té,

 alors q

ue l'

air intérie

ur est c

limatis

é, le VRC 

aide à

 refroi

dir l'a

ir 

neuf

 qui a

rrive,

 grâ

ce à

 la t

empéra

ture

 plus

 ba

sse

 de l'

air vicié

 qui e

st év

acué

Aut

o-vé

rif

ication

 - 

Cha

que fois q

ue le VRC 

est

 mis

 sous t

ens

ion, la

 fonct

ion d'

aut

o-vé

rifica

tion 

est

 

auto

matique

ment 

act

ivée

. Le

 VRC pa

sse

 par t

outes

 les vit

ess

es d

isponib

les et 

vérif

ie le

    

fonctionne

ment 

du mo

teur d

u registre

. Le

 VRC re

vient 

ens

uite à

 son mod

e d

e fo

nctionne

ment 

    

antéri

eur et 

à la

 vites

se c

hoisie

 (après

 enviro

n 60 se

conde

s).

  

Mode d'

atte

nte 

(V

itesse

 0)

 - 

Le VRC 

est

 mis

 sous t

ens

ion et

 att

end 

que la ve

ntilation 

soit

    

act

ionnée p

ar l'int

ermé

diaire

 d'une

 comma

nde ex

terne

 (pa

r ex. une

 minu

terie

) ou 

du dés

humi

distat. 

Réglez la

 comm

ande p

rincipa

le à

 la vit

ess

e 0 

pour q

ue le VRC 

soit

 en mo

de d'a

tte

nte (st

andb

y). 

Minut

erie

s

 - 

Ces c

omma

ndes o

ptionne

lles p

euv

ent 

être

 insta

llées

 à d

es p

oints d

'éva

cuation 

spécif

iques (

salle

s d

e b

ains

, etc

.) 

afin d

e d

écl

enche

r, le

 cas

 échéant,

 la ha

ute vitesse

Vous

 tr

ouver

ez 

d'aut

res

 inf

orm

ations

 ut

iles

 en vi

sita

nt le

 site 

www.lif

ebr

eat

h.com. 

Gar

antie

 

Les ve

ntilate

urs à

 récupéra

tion 

de chale

ur Lifebrea

th d

e la

 Série

 MAX 

bénéficie

nt d'

une g

ara

ntie à 

vie sur le

 noya

u récupé

rate

ur de c

hale

ur et d'une

 gara

ntie de c

inq (5

) ans

 pour 

les p

ièce

s d

recha

nge. 

Pour en

registrer vot

re g

ara

ntie

, vis

itez le

 site www.

lifebrea

th.c

om ou a

ppele

z le 1

-855

-24

7-4200 

(sans

 frais

). 

N.B

. :

  Vous

 deve

z a

voir 

les numé

ros de m

odèle

 et de sé

rie d

u VRC 

pour va

lider l

a g

ara

ntie

 auprès

 

de la c

ompagnie

 Airia.

 

12

 

Summary of Contents for max series

Page 1: ...511 McCormick Blvd London ON Canada N5W 4C8 General Info Tech Support 1 855 247 4200 Online www lifebreath com MAX SERIES HOMEOWNERS GUIDE 69 MAX OWNERS 012616 ...

Page 2: ...12 Model___________________________________ Serial Number____________________________ Dealer Contractor Information Dealer_________________________________ Installer________________________________ Telephone Contact_______________________ Installation Date_________________________ Register your HRV for warranty at www lifebreath com For any warranty information please contact Airia Brands 511 McCo...

Page 3: ...tilation mode at low speed for low household activity levels or when the home is unoccupied This mode is useful when 20 40 mode is providing too much ventilation V Continuous Recirculation This mode continuously recirculates your household air no ventilation This mode is not applicable if your HRV is connected to a forced air system Recirculation Recirculates existing household air without introdu...

Page 4: ...rs only when the outdoor air is dryer than the indoor air Your Lifebreath Digital Control has an adjustable Dehumidistat which can be set to achieve a further dehumidification effect from your HRV High speed ventilation will be initiated upon exceeding the Dehumidistat set point regardless of the mode and speed of operation Once the humidity in the house is reduced the HRV will revert back to its ...

Page 5: ...d Button Press and release the 20 40 60 High Speed button to temporarily initiate HIGH Fan speed for 20 40 or 60 minutes Press once for 20 minutes twice for 40 minutes 3 times for 60 minutes and 4 times to disable The will appear on the screen and the corresponding section of the clock will flash to indicate the time interval selected When the timer runs out the unit will return to it s previous o...

Page 6: ...at settings and set the unit into LOW fan speed Ventilation mode and a Dehumidistat setting of 40 Service Indicator A service indicator appears when the unit requires routine maintenance Refer to Maintenance Routine in this guide To reset the service indicator once routine maintenance has been performed press and hold the ON OFF button for 5 seconds Timers Depending on the type of HRV installation...

Page 7: ... on the Timer to indicate either 20 40 or 60 minutes of high speed fan operation To cancel the call for high speed fan operation press the Select Button until the Status Lights are no longer illuminated Replacing the Battery When the battery on the timer needs to be replaced in the Wireless Timer the red LED Battery Indicator will illuminate To replace the battery first remove the Face Plate by pu...

Page 8: ...Indicator LED s When the Repeater is positioned correctly a solid green LED will illuminate indicating the Repeater has a strong connection to the main wall control and may be moved farther away if necessary A flashing green LED means that the Repeater has a moderate connection to the main wall control The Repeater will function properly at this position but should not be moved farther from the ma...

Page 9: ...utward Core may be snug but will slide out of the cabinet c Once removed from the cabinet remove filters d Install the clean filters e Install clean core in the cabinet Note Core installation label on the outer end of the core To Install the Clean Core a To reinstall the core first position the bottom of the core on the bottom support in the cabinet b Carefully align the core with the other 3 supp...

Page 10: ...water and replace if worn bent or unable to clean 6 Clean Duct Work if Required The duct work running to and from the HRV may accumulate dirt Wipe and vacuum the duct once every year You may wish to contact a heating ventilation company to do this 7 General Maintenance Twice a Year Wipe down the inside of the cabinet with a damp cloth to remove dirt bugs and debris that may be present 10 ...

Page 11: ...d fall HRV is set at too low a speed Set dehumidistat lower Cover pools hot tubs when they are not in use Avoid hanging clothes to dry storing wood and venting clothes dryer inside Fire wood may have to be moved outside Vent crawl space and place a vapor barrier on the floor of the crawl space On humid days as the seasons change some condensation may appear but the homes air quality will remain hi...

Page 12: ... HRV cycles through the available speeds and tests the damper motor operation The HRV resumes operation at the selected mode and speed Approximately 60 seconds in duration Standby Speed 0 The HRV is on but fans are not running waiting for ventilation to be initiated by either an external control i e timer or the dehumidistat Set the main control to speed 0 to set the HRV in standby Timers These op...

Page 13: ...ie le fonctionnement du moteur du registre Le VRC revient ensuite à son mode de fonctionnement antérieur et à la vitesse choisie après environ 60 secondes Mode d attente Vitesse 0 Le VRC est mis sous tension et attend que la ventilation soit actionnée par l intermédiaire d une commande externe par ex une minuterie ou du déshumidistat Réglez la commande principale à la vitesse 0 pour que le VRC soi...

Page 14: ...éshumidistat plus bas couvrez la piscine et le hot tub quand vous ne vous en servez pas évitez d étendre du linge à sécher d emmagasiner du bois et de ventiler la sécheuse à linge à l intérieur vous devrez peut être sortir le bois de chauffage dehors aérez l espace sanitaire et mettez un pare vapeur sur le plancher de cet espace sanitaire par temps humide lorsque les saisons changent il pourrait y...

Page 15: ...t trop usé faussé ou impossible à nettoyer 6 Nettoyez les canalisations au besoin Il pourrait y avoir une accumulation de saleté dans les canalisations reliées au VRC En plus de vous servir d un aspirateur essuyez les canalisations une fois par année Vous pourriez aussi confier cette tâche à une entreprise spécialisée en chauffage et climatisation 7 Effectuez un entretien général deux fois par ann...

Page 16: ...peu serré il vous sera possible de le sortir de sa coulisse c Une fois que vous l avez sorti de l armoire enlevez les filtres d Remettez les filtres propres en place e Réintroduisez le noyau nettoyé dans l armoire de l appareil Remarque L étiquette d installation du noyau doit être à son extrémité extérieure Pour remette le noyau nettoyé dans l appareil a Placez d abord le bas du noyau sur son sup...

Page 17: ...t positionné correctement une DEL verte s allume pour indiquer un signal fort entre le répéteur et la commande murale principale et qu il peut être déplacé plus loin si nécessaire Une DEL verte clignotante indique que le répéteur a un lien plus faible avec la commande principale le répéteur peut fonctionner correctement à cet endroit mais ne devrait pas être plus éloigné de la commande principale ...

Page 18: ...emplacement éloigné dans la maison comme une salle de bains En appuyant sur le bouton select de la minuterie on enclenche le fonctionnement du ventilateur à haute vitesse Le témoin correspondant s allume sous les nombres qui indiquent soit 20 40 ou 60 minutes de fonctionnement du ventilateur à haute vitesse Pour annuler la demande de fonctionnement à haute vitesse appuyez sur le bouton select jusq...

Page 19: ...Indicateur d entretien Un signal apparaît lorsque arrive une étape de maintenance régulière reportez vous à Entretien périodique dans ce guide Pour réinitialiser le rappel une fois la maintenance effectuée maintenez le bouton de marche arrêt enfoncé pendant 5 secondes Minuteries Selon le genre d installation à VRC vous pourriez profiter d une minuterie optionnelle dans divers endroits de la maison...

Page 20: ...t Bouton réinitialisation Bouton haute vitesse 20 40 60 Fonctionnement du commande numérique DXPL02 Mise en marche de la commande Appuyez et relâchez le bouton Marche arrêt Le témoin s allume au dessus Réglage de la vitesse de ventilation Appuyez sur et relâchez le bouton du ventilateur pour sélectionner l une des vitesses de ventilateur 5 La vitesse du ventilateur s affiche à l écran à côté du sy...

Page 21: ...ité excessive à l intérieur en déclenchant la ventilation à haute vitesse dès que le point de consigne réglable du Déshumidistat est dépassé Consultez la section portant sur la commande principale dans le Guide d installation pour savoir comment régler le Déshumidistat Étant donné qu on obtient un effet de déshumidification seulement lorsque l air extérieur est plus sec que l air intérieur la fonc...

Page 22: ...ive parfois que des habitations soient câblées incorrectement Vous devez toujours vous assurer que l appareil est bien mis à la terre Attention À cause de notre programme continu de recherches et de perfectionnement des produits les caractéristiques les puissances nominales et les dimensions peuvent être modifiées sans préavis Consultez le www LIFEBREATH com pour les toutes dernières informations ...

Page 23: ...__ Numéro de série ___________________________ Renseignements au sujet du concessionnaire et de l entrepreneur Concessionnaire ________________________ Installateur ____________________________ Téléphone Contact ____________ Date d installation ______________________ Pour enregistrer la garantie de votre VRC visitez le site www lifebreath com Si vous avez besoin d informations au sujet de la garan...

Page 24: ...511 boul McCormick London ON Canada N5W 4C8 Information générale support technique 1 855 247 4200 En ligne www lifebreath com SÉRIE MAX GUIDE POUR LES PROPRIÉTAIRES 69 MAX OWNERS 012116 ...

Reviews: