background image

31

 

|

 

P a g e

 

 

21X8

 

Idler

 

Spacer

   

3

 

2X92

 

LifeCore

 

Sticker

 

1

 

22FT

 

Idler

 

Wheel

 

Bracket

 

Assembly

   

1

 

2XBA

 

Heart

 

Rate

 

Transmitter

 

belt

 

1

 

22LR

 

C

RING

 

A

16

 

T=1.2

 

 

 

1

 

2XCP

 

Boot

   

2

 

22QV

 

M10*1.5

20

 

Screw

   

4

 

2XJ3

 

Side

 

Cover

 

Sticker

 

(Right,

 

Outside)

   

1

 

22RR

 

M10*1.5,T=8

 

Nut

   

2

 

2XJ4

 

Side

 

Cover

 

Sticker

 

(Left,

 

Outside)

 

1

 

25B1

 

M5*0.8

25

 

Screw

 

3

 

2XJA

 

Upper

 

Support

 

Tube

 

Wire

 

1

 

25VV

 

C

RING

 

B

47

 

 

4

 

2XJB

 

Lower

 

Wire

 

Cable

 

1

 

27JR

 

M5*0.8

6

 

Screw

   

4

 

2XJD

 

Console

 

Mast

 

Frame

   

1

 

27S2

 

Adjustable

 

Stabilizer

 

Foot

   

4

 

2XJS

 

Upper

 

Support

 

Tube

 

1

 

29M9

 

Heart

 

Rate

 

Sensor

 

Rubber

 

Pad

 

2

 

2XJU

 

Side

 

Rails

 

2

 

2AX2

 

Mobility

 

Wheel

   

2

 

2XKV

 

Heart

 

Rate

 

Cable

 

1

 

2CRJ

 

Crank

 

Shaft

   

1

 

2XL7

 

Left

 

Outside

 

Cover

 

Assembly

 

1

 

2CTC

 

Linking

 

Seat

   

2

 

2XL8

 

Right

 

Outside

 

Cover

 

Assembly

 

1

 

2CTQ

 

Drive

 

Pulley

 

Wheel

 

Right

 

1

 

2XLC

 

Heart

 

Rate

 

Handlebar

 

Assembly

 

1

 

2CTS

 

Drive

 

Pulley

 

Wheel

 

Main

 

Left

   

1

 

2XLD

 

End

 

Cap

   

2

 

2CU3

 

Center

 

Shaft

 

Washer

   

2

 

2XLH

 

M6*1.0

16

 

Bolt

   

6

 

2CU7

 

M12*1.75

30

 

Bolt

   

4

 

2XLK

 

M6*1.0

50

 

Screw

   

6

 

2CU8

 

Rolling

 

Wheel

   

2

 

2XLS

 

Sticker

 

Rear

 

Cover

 

(Upper)

 

1

 

2CU9

 

Collar

   

2

 

2XLV

 

Program

 

Sticker

 

1

 

2D2F

 

Side

 

Cover

 

(Right,

 

Outside)

 

1

 

2XLW

 

Heart

 

Rate

 

Sticker

 

1

 

2D2G

 

Side

 

Cover

 

(Right,

 

Inner)

 

1

 

2XP4

 

Linkage

 

Arm

 

Frame

 

Right

   

1

 

2D2H

 

Side

 

Cover

 

(Left,

 

Outside)

 

1

 

2XP6

 

Linkage

 

Arm

 

Frame

 

Left

   

1

 

2D2J

 

Side

 

Cover

 

(Left,

 

Inner)

 

1

 

2XQ2

 

Right

 

Lever

 

Arm

 

Frame

   

1

 

2D2K

 

Disc

 

Cover

   

2

 

2XQH

 

LifeCore

 

Sticker

 

2

 

2D38

 

Cover/Water

 

bottle

 

Holders

 

1

 

2XQQ

 

Main

 

Frame

 

Assembly

 

1

 

2D39

 

Right

 

Cover

 

Water

 

Bottle

   

1

 

2XRR

 

Serial

 

Number

 

Sticker

   

1

 

2D3C

 

Shaft

 

Cover

 

(Right)

 

2

 

2XRS

 

Left

 

Lever

 

Arm

 

Frame

 

1

 

2D3E

 

Shaft

 

Cover

 

(Left)

 

2

 

2XW3

 

Owner’s

 

Manual

 

1

 

2D3F

 

Bracket

 

Cover

   

2

 

2XXK

 

Computer

 

Console

 

Assembly

 

1

 

2D40

 

Left

 

Cover

 

Water

 

Bottle

   

1

 

2XXQ

   

Right

 

Lever

 

Arm

 

Assembly

 

1

 

2D41

 

Rear

 

Cover

   

1

 

2XXR

 

Left

 

Lever

 

Arm

 

Assembly

 

1

 

2D4Z

 

Side

 

Rail

 

Rubber

 

Guard

 

2

 

2XXT

 

Linkage

 

Arm

 

Right

 

Assembly

 

1

 

2D6R

 

M10*1.5

95

 

Bolt

   

1

 

2XXV

 

Linkage

 

Arm

 

Left

 

Assembly

 

1

 

2DAK

 

Drive

 

Belt,

 

Poly

V

 

Belt

 

PJ450

 

1

 

2Y0C

 

Pedal

 

Tube

 

Assembly

 

Tube

 

Right

 

1

 

2DAM

 

M5*0.8

65

 

SCREW

 

2

 

2Y0D

 

Pedal

 

Tube

 

Assembly

 

Tube

 

Left

 

1

 

2DFX

 

Rear

 

Cover

 

(Upper)

   

1

 

2Y43

 

Shaft

 

Sleeve

 

Assembly

 

2

 

Summary of Contents for LC-CD600

Page 1: ...Core Fitness Inc 2575 Pioneer Ave Suite 101 Vista CA 92081 Serial Number is located on the frame Please send in the attached warranty card Page 33 and a copy of the original receipt or register online...

Page 2: ...2 P a g e...

Page 3: ...re 6 Page 11 Assembly Figure 7 Page 12 Assembly Figure 8 Page 13 Assembly Figure 9 AC Adaptor Location Page 14 Computer Console Instructions Page 15 Monitoring Your Heart Rate Page 22 How To Properly...

Page 4: ...enance tips to keep the product in good working order Make sure that all components are fastened securely including but not limited to pedals handlebars or computer It is recommended the unit be plugg...

Page 5: ...tector Unpack the box in a clear work area to allow smooth assembly Remove all the parts from the packing material however do not discard packing material until assembly is complete Double check packi...

Page 6: ...ly please call LifeCore Fitness at 1 888 815 5553 FIGURE 1 Tools Needed 6mm Allen wrench 0J3V Note It is recommended that two adults help during this step One person holds the upper support tube assem...

Page 7: ...Figure 2 Slide the left side rail into the upper support tube assembly attached the top left side rail using Qty three M6x1 16 bolts and Qty three 6x13 washers Attach the lower portion with Qty three...

Page 8: ...labeled Figure 3 Locate the right and left Handrail Linkage Assemblies See Figure 3 Slide the left handrail linkage assembly on to the lever arm frame Using Qty one 10 2x35 washer Qty one 10 lock wash...

Page 9: ...and align holes Additional help may be needed to help align holes Secure linkage to unit using Qty four M8x1 25 12 hex bolts two on top and two on the bottom Use 6mm Allen wrench to tighten the M8x1...

Page 10: ...assembly to the handrail assembly with Qty one M10x1 5 81 5 hex bolt and Qty one M10x1 5 hex nut Using the 17mm socket wrench and 17mm wrench tighten bolt and nut snug Not Too Tight Please ensure that...

Page 11: ...cate console mast and slide console mast into upper support tube assembly make sure computer cable wire slides down straight and does not get pinched Connect the computer cable wire coming from the co...

Page 12: ...and connect that to the grounding terminal to the left of the 7 pin connector Locate the 3 pin heart rate cable and heart rate ground wires Connect the 3 pin wire to the 3 pin connector on the board...

Page 13: ...6mm Allen wrench 0J3V Locate bag labeled Figure 8 Locate left and right handlebars See Figure 8 Attach left handlebar to handlebar assembly using Qty three M8 16mm hex bolts Using a 6mm Allen wrench...

Page 14: ...nit No other power supply should ever be used to power the machine 14 P a g e Once assembly is complete if needed tighten or loosen the levelers on the bottom of the machine to prevent the machine fro...

Page 15: ...in Calories Pulse Resistance Level and Cal Hour Profile Window Displays program profile tension bar heart rate Bar HR Programs Only lap progress display and lap counter The profile window toggles betw...

Page 16: ...in each of the windows The Console default time will continue to count down until time has reached 0 00 During non heart rate programs the profile window will toggle between the program profile and th...

Page 17: ...s button to confirm Note Default weight is 150 Pounds Weight settings can range from 70 LBS to 330 LBS AGE Once weight has been entered age will show in message window Use the or buttons to select age...

Page 18: ...to select Next weight will be displayed adjust for weight using the arrows GLUTE BLASTER Will gradually take a user to the highest resistance peak then gradually bring the tension level back to the be...

Page 19: ...eart Rate program In all Heart Rate Control programs the console only accepts the wireless heart rate signal from a chest strap transmitter The heart rate hand pulse grips function is disabled during...

Page 20: ...ar workout HR 65 FAT BURN Maintains your Target Heart Rate at 65 of Max Heart Rate by automatically adjusting the tension levels to maintain that percentage This is a good program for people who want...

Page 21: ...ition on the virtual track will blink The tension level will be displayed in the first column Every dot in the tension column will represent an increment of one or two tension levels Tension level goe...

Page 22: ...of exercising the AHA recommends aiming for the lower part of the target heart rate zone 60 then gradually progressing up to 75 According to the AHA exercising above 75 of your maximum heart rate may...

Page 23: ...acemaker or if you are taking medications for a heart condition Medication or electrical pulses from the pacemaker can interfere with accurate heart rate readings Do not bend the chest strips This can...

Page 24: ...ection with your body When you start to sweat the connection may improve 9 Check to see if battery is still working The estimated average battery life of the transmitter is 2000 hours of use If the ba...

Page 25: ...resistance cable and make sure that it is connected to the magnetic flywheel servo motor correctly 9 If the motor is still not changing resistance the computer and or servo motor may need to be replac...

Page 26: ...get a different position 9 If just putting on the chest strap wait a few minutes for the transmitter gets a good connection with your body When you start to sweat the connection will improve 9 Check...

Page 27: ...level with the ground Adjust as needed to level machine 9 If unit is placed on hard surface the machine will need to have a mat placed under the machine to prevent the leveler feet from breaking and t...

Page 28: ...dry towel or use a light house hold cleaner such as Windex to remove dirt The purpose of cleaning the unit is to remove body sweat which contains salt Salt is the number one factor that will cause the...

Page 29: ...2 29 P a g e...

Page 30: ...RING A 17 4 2J78 M8 1 25 12 Bolt 24 0JEG C RING A 20 1 2JAW 17mm Wrench 1 0JEJ C RING A 25 2 2JAW 17mm Socket Wrench 1 0K2C M8X1 25 16 Screw 4 2JN1 Handrail Right Upper Assembly 1 0K2W M5 0 8 16 Screw...

Page 31: ...lt 4 2XLK M6 1 0 50 Screw 6 2CU8 Rolling Wheel 2 2XLS Sticker Rear Cover Upper 1 2CU9 Collar 2 2XLV Program Sticker 1 2D2F Side Cover Right Outside 1 2XLW Heart Rate Sticker 1 2D2G Side Cover Right In...

Page 32: ...Service Notes and History 32 P a g e...

Page 33: ...transportati e Wear items rmal usage L nt improper m nance LifeCo n authorized L riod Your rem usly registered he address be he serial numb er s remaining ranty this prod nsferred warra ime of reques...

Reviews: