3
Sea Horse Pump Installation and User’s Guide
13. It is essential that the suction line be free of air leaks and air traps.
14. Suction fittings must conform to ASME/ANSI A 112.19.8 M Standards. Use double suction fittings.
15. The maximum operating pressure of this unit is 25 pounds per square inch. Never operate this pump
above this pressure.
This pump is not intended to be operated in series with other pumps.
WARNING
DO NOT permit children to use this product.
16. Wiring of this pump should be performed by a licensed electrician in accordance with the National
Electrical Code or your local electrical code.
WARNING
Never work on pump while it is running or power is still connected; hazardous voltage can cause severe or fatal injury.
A suitable ground fault interrupter should always be installed at the power supply source of the unit.
WARNING
Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical
shock hazard. Do not ground to a gas supply line.
17. The pump motor must be wired for the proper voltage in accordance with the wiring diagram supplied
with the motor.
WARNING
Wiring the motor with the incorrect supply voltage will cause damage to the motor
and void the warranty.
18. The wiring to the motor should be kept as short as possible and large enough NOT to cause an
excessive voltage drop. Use the wire size table as a guide in selecting minimum conductor size.
19. Install, ground and bond wire according to local or National Electrical Code requirements.