TROUBLESHOOTING
DIGITAL WINDOW FAULT CODE
Fault indication: ice full light flashes quickly: ambient temperature (sensor) fault, shutdown
.
The ice full indicator and the water shortage indicator flash alternately: the open and
closed signals of the ice full switch cannot be detected for 3 consecutive times, the
machine stops working and reports a mechanical failure.
FAULT SELF-DIAGNOSIS
1. Water pump-You can directly observe whether water flows down from the ice tray. If
not, the water pump may malfunction.
2. Ice making——After the ice-making last running for 10 minutes, the water in the water
tank will become noticeably cold. You can directly touch the ice tray or running water to
feel the water temperature.
3. Water inlet-During the automatic cleaning process, it can be observed that water
continuously flows into the ice storage bucket from the overflow pipe of the water tank.
During the ice making process, you can reach into the water tank with your hand to feel
the amount of water, which normally accounts for more than half of the water tank.
4. If your ice maker uses tap water to make ice, and finds that the water can’t be stopped.
Please check your house water pressure. You need a pressure relif valve to control the
water pressure.
- 22 -
- 19 -
service@lifepluspro.com
service@lifepluspro.com
Problem
Possible cause
Solution
Ice maker
does not
start
Ice maker
stops after
running
The
production
of ice
cubes
decreased
Bad socket contact
Change socket
The ice bin is full of ice
cubes
Remove the ice cubes
Adjust the flap to enable
The flap is not reset
reset free
Water source is not turned
on or connected not strong
Recheck water resource
Ice maker is not located
horizontally
Adjust the feet and locate
them horizontally
Over temperature
shutdown protection
Remove the front panel
and clean the condenser
Not cleaned up for more
than two months
Remove the front panel
and clean the condenser
High water temperature
(Possible in summer)
Ambient temperature is too
high
Move it to a cool room
Small or closed
environmental spaces
Clean surrounding and
allow air to circulate
FAULT SELF-DIAGNOSIS
Do not use hot water
Water overflow in the
inside tank
Check valve again and
reset the water level float