background image

A8 / A8P Installation Manual

6

7

 

FlexPower System Replacement Parts

Board Kits

Order #

Description

FPO250

A01-007

FPO250 replacement board

FPO150

A01-005

FPO150 replacement board

FPO75

A01-003

FPO75 replacement board

B100

A03-009

DC-DC Convertor (12VDC or adjustable 5 to 18VDC) replacement board

D8

A02-001

Simple distribution replacement board

D8P

A02-002

Simple distribution (Class 2) replacement board

F8

A02-003

FAI controlled distribution replacement board

F8P

A02-004

FAI controlled distribution (Class 2) replacement board

C4

A02-005

Four zone power control replacement board

C4P

A02-006

Four zone power control (Class 2) replacement board

C8

A02-007

Eight zone power control replacement board

C8P

A02-008

Eight zone power control (Class 2) replacement board

N24

A04-001

Two Input, 4 Output NAC Expander accessory replacement board

NL2

A11-

NetLink network communication board (used in FPO systems)

NL4

A11-

NetLink network communication board (used in FPO systems)

NLR

A11-002

NetLink network communication kit / remote reset (used in FPA systems)

NS2

A11-003

Reset module board for use with NL1

RB2

A25-001

2A Relay, 12VDC or 24VDC input range, DP/DT

RB5

A25-002

5A Relay, 12VDC or 24VDC input range, DP/DT

RB8

A25-003

8A Relay, 12VDC or 24VDC input range, DP/DT

Hardware

Order #

Description

DL1

A05-001

DataLink USB cable

BDM

A05-006

Battery Disconnect Module cable

AC Cable

A05-005

AC Input Cable for FPO Power Supply

Battery Cable

A05-002

Battery Harness – 24"

Module Cable - 12"

A05-003

Accessory board cable set – 12"

Module Cable - 18"

A05-004

Accessory board cable set – 18"

Fuse - 3A

A05-201

ATM-3A Fuse – Bag of 25

Fuse - 5A

A05-202

ATM-5A Fuse – Bag of 25

Fuse - 7.5A

A05-203

ATM-7.5A Fuse – Bag of 25

Fuse - 10A

A05-204

ATM-10A Fuse – Bag of 25

Fuse - 15A

A05-205

ATM-15A Fuse – Bag of 25

Fuse - 30A

A05-206

ATM-30A Fuse – Bag of 25

Standoffs

A05-301

Nylon Standoffs – Bag of 25

Camlock Set

A05-302

Key and Lock fits LSP "E" enclosure

Summary of Contents for FlexPower A8

Page 1: ...LifeSafety Power Inc PH 888 577 2898 TechSupport LifeSafetyPower com P03 004 Rev A06 A8 A8P Installation Manual ...

Page 2: ...ent discussed within this manual has been tested to the following standards UL294 UL2044 CSA C22 2 107 1 Mounting the A8 Power Distribution Accessory Mounting of the board to an enclosure is via the four snap in standoffs supplied 1 Locate the appropriate mounting holes in the enclosure and snap the standoffs into the holes 2 Align the board mount ing holes with the standoffs be sure the PC board ...

Page 3: ...e their BR fastons wired together for proper operation except for between the DC and AC sections of an FPX hybrid system 4 Output Selection Jumpers JP1 JP8 These jumpers select which voltage buss input is select ed for the output Jumper numbers correspond with the zone number e g JP1 is the jumper for OUT1 Possible settings are as follows Position 2 Left B2 Buss Position 1 Right B1 Buss Removed Di...

Page 4: ...er set in Position 2 will have a continuous 28VAC output This application shows dual A8 s for sixteen zone distribution The B1 input is connected to the blue lead 24VAC output of the FPA dual tapped transformer B2 input is connected to the orange lead of the FPA transformer for 28VAC output Any zone output with its jumper set in Position 1 will have a continuous 24VAC output Any zone output with i...

Page 5: ...5 2 1 JP6 2 1 JP7 2 1 JP8 2 1 B1 B2 BR B1 B2 BR B1 B2 BR B1 B2 BR OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 JP1 2 1 JP2 2 1 JP3 2 1 JP4 2 1 JP5 2 1 JP6 2 1 JP7 2 1 JP8 2 1 A8 Application Examples Typical 300VA 16 outputs with zone select 24 28V AC power ...

Page 6: ...AGE will occur JP1 2 1 JP2 2 1 JP3 2 1 JP4 2 1 JP5 2 1 JP6 2 1 JP7 2 1 JP8 2 1 i OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 JP1 2 1 JP2 2 1 JP3 2 1 JP4 2 1 JP5 2 1 JP6 2 1 JP7 2 1 JP8 2 1 B1 B2 BR B1 B2 BR B1 B2 BR B1 B2 BR A8 Application Examples Typical 600VA 16 outputs with zone select 24 28V AC power ...

Page 7: ...unication board used in FPO systems NL4 A11 NetLink network communication board used in FPO systems NLR A11 002 NetLink network communication kit remote reset used in FPA systems NS2 A11 003 Reset module board for use with NL1 RB2 A25 001 2A Relay 12VDC or 24VDC input range DP DT RB5 A25 002 5A Relay 12VDC or 24VDC input range DP DT RB8 A25 003 8A Relay 12VDC or 24VDC input range DP DT Hardware Or...

Page 8: ... its distributors be liable for any incidental indirect or consequential damages arising from the sale resale use or misuse of the product Specifications are subject to change without notice In addition LifeSafety Power reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification LifeSafety Power FlexPow...

Reviews: