Water Filter Specifications

ScaleSolver Specifications

49.5”

8”

810 Commercial Water System Overview

Equipment 

Specifications 

52”

8”

B

Y

PA

SS

B

Y

PA

SS

The 810 Commercial ScaleSolver is self-contained and ready 
to use. A simple inlet and outlet connection is all that is 
required for installation. No backwash is necessary.  

• Inlet Connection   

      1” PVC Union with Socket

• Outlet Connection 

     1” PVC Socket

• Max. Dimensions

      

49.5“ x 8”

• Max. Flow Rate

          20 gpm

• Max. Temperature 

  

  100˚ F (37.8˚ C)

• Max. Pressure 

      

100 PSI

• Dry Weight 

                17 lbs.

• In-Service Weight       

  90 lbs.

* Chlorine must not be above 3.0 PPM. 

The 810 Commercial Water Filter is a no maintenance, 
whole facility water filtration system. This system includes a fully 
automatic valve head that runs a self-rinsing cycle every 14-days. 

• Inlet Connection

        1” 

• Outlet Connection 

    1” 

• Max. Dimensions 

     

52” x 8”

• Max. Flow Rate 

         10 gpm

• Max. Temperature   

  140˚ F 

*In areas where outside temperatures are less than 32°F 

for an extended period of time, insulation is required

• Max. Pressure   

    

Min. 40 psi, Max. 100 psi

• Dry Weight       

          39 lbs.

• In-Service Weight       

  115 lbs.

Power Requirement:

 

1 standard 110v electrical outlet within 5’ of system

or a 24v transformer plugged into a more distant 

electrical outlet. 

Filter 

ScaleSolver

Ver. 8.6.16

Summary of Contents for 810 Series

Page 1: ...c 787179 NV Lic 059578 LifeSource Water Systems Inc 523 S Fair Oaks Ave Pasadena CA 91105 LifeSourceWater com Customer Service 626 792 9996 Model 810 Commercial Water System Installation and Operations Guide ...

Page 2: ... In Service Weight 90 lbs Chlorine must not be above 3 0 PPM The 810 Commercial Water Filter is a no maintenance whole facility water filtration system This system includes a fully automatic valve head that runs a self rinsing cycle every 14 days Inlet Connection 1 Outlet Connection 1 Max Dimensions 52 x 8 Max Flow Rate 10 gpm Max Temperature 140 F In areas where outside temperatures are less than...

Page 3: ...efrigerator water line beneath the sink and on any other water lines in the building Any such filters if retained should be routinely changed per manufacturers recommendations A suitable outlet to drain the rinse water must be made available for filter That outlet can either be a ground location that has a sufficient percolation a driveway or a drain DO NOT CONNECT THE FILTER RINSE LINE TO AN AIR ...

Page 4: ... close attention to the direction of the arrows on each valve head 2 First begin with the ScaleSolver by opening up the inlet valve first and then the outlet valve NOTE The ScaleSolver unit operates in the UPFLOW mode which is opposite of a conventional softener Both the inlet and outlets are clearly marked on tank 3 As the ScaleSolver fills with water allow cold water to run through a faucet or h...

Page 5: ...illed about 4 apart along the pipe lying on the ground to better distribute the water in a garden area DO NOT cap the end of the pipe or connect the end of the pipe to a drip line NOTE If using the 24 volt transformer run wire and make connections but do not plug in 9 Turn on the main water supply and check all connections for leaks NOTE After installing the filtration tank it is extremely importa...

Page 6: ...ver to the SERVICE position The water will continue the self cleaning cycle Leave the bypass lever in the SERVICE position MANUAL RINSE CYCLE INSTRUCTIONS 4 Rotate the control knob at the top of the tank SLOWLY clockwise to RAPID RINSE between 4 and 5 o clock Stop and leave it on RAPID RINSE for 2 to 3 minutes Water will be running out the rinse line during this time See Figure 5 5 Then turn the c...

Page 7: ...grammed to self rinse once every 14 days for 30 minutes between 2 a m and 3 a m Water pulled into the building at this time will not be filtered by the system If you would like self rinsing to occur at a time other than 2 a m you must adjust the TIME OF DAY For example if you would like self cleaning to occur between 12 a m and 3 a m which is two hours earlier than programmed you must set the TIME...

Page 8: ...water to run until it is fairly cool Consult your manufacturer instruction manual for draining tankless water heaters Immediately After Installation Traditional Water Heaters Boilers Tankless Water Heater Water Doesn t Taste Right Check Bypass See if the bypass on BOTH TANKS are in the service position See Figure 10 11 Check Electrical Make sure power plug on the WATER FILTER is plugged into elect...

Page 9: ...o use single use dishwasher detergents Pods Packs or Tabs These will overwhelm your dishwasher with excess soap Excess soap will cause excess water spots and glazing We recommend Cascade Complete One teaspoon of Cascade Complete detergent and 1 teaspoon of Sour Salt Citric Acid or Glass Magic as a rinsing agent will produce excellent results Lime or Soap Scum Buildup If you currently have lime bui...

Page 10: ...rees F 3 That failure has not resulted from misuse alteration freezing accident fire or neglect The automatic timer valve used by LifeSource Water Systems has a three year warranty on parts if installed as required by the manufacturer There will be no service charge for the first 90 days if installed by the factory WATER PRESSURE EXCEEDING 100 PSI CAN DESTROY THE INNER WORKINGS OF THE TANK AND VAL...

Page 11: ...tion for Gas and Water The ScaleSolver system including the tank media and valve head is warranted for performance for a period of three years from the date of the original installation The ScaleSolver warranty is four years when installed in conjunction with a LifeSource Water System in the proper configuration LifeSource Water Systems Inc warrants the ScaleSolver system as follows Our obligation...

Reviews: