- 15 -
PROBLEMS CHECK LIST
PROBLEM
PROBABLE CAUSE
SOLUTION
Pilot will not light
Gas valve maybe OFF
Turn the gas valve ON
Tank fuel empty
Refill LPG tank
Opening blocked
Clean or replace opening
Air in supply system
Purge air from lines
Loose connections
Check all fittings
Pilot will not stay on
Debris around pilot
Clean dirty area
Loose connections
Tighten connections
Thermocouple bad
Replace thermocouple
Gas leak in line
Check connections
Lack of fuel pressure
Tank near empty. Refill LPG tank.
Burner will not light
Pressure is low
Tank near empty. Refill LPG tank.
Opening blocked
Remove and clean
Control not ON
Turn valve to ON
Thermocouple bad
Replace thermocouple
Pilot light assembly bent
Place pilot properly
Not in correct location
Position properly and retry
Manufactured by:
Changzhou Gardensun Furnace Co., Ltd.
No. 1, Boyi Town, Changzhou City,
Jiangsu Province P.R. China
Tel: 86-519-3317471
Fax: 86-519-3315116
MODEL
HPS-B
Destination Countries
BE-CH-ES-FR-GB-IE-IT-PT
Category
I3+
M/bar
28-30/37
Power
4.0 Kw
CE 0407
Certificate No: 27750/441/C To BSEN : 14543:2002