- 7 -
VISUALLY CHECKING BURNER FLAMES
The flame pattern at the emitter grid should be visually checked whenever the appliance is operated.
Under the following conditions the appliance should be turned off immediately and NOT operated
again until repair are made:
When the pilot flame extends more than 1/2 inch beyond surface of the emitter grid.
When black soot accumulates on the emitter grid.
OPERATION AND STORAGE
TO TURN ON THE HEATER
1.
Turn on the gas supply at the regulator by turning the lever on the regulator to the
“ on “ position. This is after you have correctly fixed your regulator to your gas bottle.
2.
Firmly press down and turn the variable control knob for approximately
45°(counter anti-clockwise).
3.
Press down the variable control knob and hold for 20 seconds. while holding
down the variable control knob, press the igniter button several times until
the pilot flame comes on. Release the variable control knob after the pilot flame lights.
4.
If the pilot does not light, repeat step 2 to 3.
Note: If a new tank has just been connected, please allow at least one minute for the air in
the gas pipeline to purge out through the pilot hole.
5.
After the flame comes on , leave the variable control knob at minimum position for about 5
minutes, then switch to a desire temperature position.
TO TURN HEATER AND PILOT OFF
1.
Turn control knob to “ON” position.
2.
Then , press down lightly and turn to “OFF” position.
3.
Turn the gas tank off completely.
TO STORE THE HEATER UNIT
1.
Turn the gas tank to complete closed position.
2.
Remove the pressure regulator and the hose attachment.
3.
Inspect the gas tank for damage. If you suspect that your tank is damaged, return it to your
gas tank supplier.
4.
Store the gas tank in a well-ventilated area. Never store the gas tank below ground(for
example, basement).
Variable Control Knob