background image

Lift-Rite, 

Tel:

 Toll Free from USA: 1-800-558-6012, Greene, NY 13778, Publication Number 1234959D ©2022                                                                    Dated 14 Sep 2022

13

INDICATOR FUNCTIONS

Graduation

From 0 to 3000 lbs. (0 to 1361 kg), the weight is shown in 1 lb. (0.5 kg) increments.

From 0 to 5000 lbs. (0 to 2268 kg), the weight is shown in 2 lb. (0.9 kg) increments.

Before Weighing: Check Zero Point

Before each weighing, it is necessary to check whether the system is unloaded and free. The 
indicator is fitted with an automatic zero correction. This means that small deviations of the zero 
point corrects automatically. If the indicator does not determine the zero point automatically, it must 
be done manually by pressing the >0< key.

Gross Weighing

After lifting a load, the display shows the gross value of the weighed load.

Net Weighing: Automatic Tare

The indicator offers the possibility to reset tare weights to zero automatically. This way added or 
subtracted weights can be determined. 

Lift  load.

Press key 

.

The indicator is set to zero.

The "NET" pointer shows that a tare weight is activated.

Place or remove the net load.

The display shows the net value of the weighed load.

When load is removed, a negative weight is shown.

By pressing the 

 key again, the gross weight is shown. 

Summary of Contents for LFTSC

Page 1: ...13778 Publication Number 1234959D 2022 Dated 14 Sep 2022 OWNER S MANUAL OPERATING INSTRUCTIONS MANUAL and REPLACEMENT PARTS MANUAL Lift Rite Legal for Trade Scale Hand Pallet Truck Model LFTSC 3P 219...

Page 2: ...es of this product until otherwise indicated in new editions Changes occur periodically to the information in this publication To order additional copies of this manual part number 1234959D contact yo...

Page 3: ...AFETY 4 SYSTEM SETUP 5 Mounting the Pump Handle 5 The Battery 6 OPERATION MANUAL 7 USING THE WEIGHING HAND PALLET TRUCK 7 Accurate Weighing 7 Taking the System into Operation 8 Maintenance 8 TOUCH PAN...

Page 4: ...anging the Thermal Paper Roll 18 Changing the Time and Date on the Print out 19 TROUBLESHOOTING 20 SPARE PARTS EXPLODED VIEW 26 SPARE PARTS LIST Weighing Hand Pallet Truck Model LFTSC 27 CALIBRATION 2...

Page 5: ...Test the manual pump for proper operation If the hydraulic pump does not respond to movement of the handle an air lock may have developed during shipping To remedy this go to the user friendly TROUBLE...

Page 6: ...ts Move loads only with the hand pallet truck in its lowest position Always make sure that the load is stable before moving to eliminate the opportunity for load shift Use extreme care when rounding c...

Page 7: ...ever is pushed down to the pump position 2 Thread the chain through the hole in the triangle and through the hole in the axle 3 Place the handle bar onto the triangle and insert the bolts 4 Tighten th...

Page 8: ...When the battery is completely empty the weighing system shuts off It is necessary to charge the battery for at least 6 hours before the first use Recharge the battery when the LO BA indicator comes...

Page 9: ...ublication Number 1234959D 2022 Dated 14 Sep 2022 7 OPERATION MANUAL USING THE WEIGHING HAND PALLET TRUCK Accurate Weighing The weight must be centered over the forks of the pallet truck and lift free...

Page 10: ...ted scale functions even though the chassis is damaged by overloading Main guidelines Because the steering wheels are mounted in the front pulling of the pallet truck is preferred above pushing it Whe...

Page 11: ...Greene NY 13778 Publication Number 1234959D 2022 Dated 14 Sep 2022 9 TOUCH PANEL INDICATOR There are three display modes lbs kg or the number of pieces Also the battery sign is integrated in the displ...

Page 12: ...t pointer bars the display shows the scale including load is stable the weight shown is negative ZERO the weight shown is within the zero range NET the display is showing the net weight e1 the weight...

Page 13: ...his means that the indicator only executes commands with a stable load Key Function level 1 short key press Function level 2 long key press Function level 3 entry mode zero setting code entry enter au...

Page 14: ...eight Err03 Gross negative This action is not allowed Automatic Err04 Out of zero range Press any key Err05 Sampling accuracy too low Press any key Err06 Input signal too high Automatic after correcti...

Page 15: ...deviations of the zero point corrects automatically If the indicator does not determine the zero point automatically it must be done manually by pressing the 0 key Gross Weighing After lifting a load...

Page 16: ...tap the 0 zero button Or Press the key until the display changes and the last digit is flashing approx 3 seconds The display shows the current tare value The right digit flashes Press the key to go up...

Page 17: ...ale and press the ENTER key The sampling is done and the display shows the total number of pieces on the scale Or Press the key or the key to change the number of pieces to add The display shows the n...

Page 18: ...o check the subtotal The display shows the net total weight and the number of weights totaled so far repeatedly for 3 seconds If the key is pressed during this period the total is printed out if optio...

Page 19: ...TOT Standard print out without code Standard print out with code B G 1234 5 lb 560 kg CODE 12345 T 34 5 lb 15 6 kg B G 1234 5 lb 560 kg N 1200 0 lb 544 3 kg T 34 5 lb 15 6 kg Nr 1 N 1200 0 lb 544 3 k...

Page 20: ...mal Paper Roll 1 Press down the two levers and pull the cover towards you to open the printer cover 2 Remove the existing paper roll Position the new paper roll making sure it unrolls in the correct d...

Page 21: ...the value until the required value is reached Press ENTER to accept the new value The display shows m_00 or the previous minute time setting with the right digit flashing Repeat the above procedure t...

Page 22: ...ing neutral and lowering do not function properly Chain anchor is out of adjustment Turn the nut on the chain anchor clockwise until the pumping action while in neutral does not raise the forks Forks...

Page 23: ...standing on or on the sides of the pallet If the readings change more than 5 lb 2 3 kg you have a mechanical problem With the forks lifted half way up the brackets for the loading wheels may touch th...

Page 24: ...d move the cable briskly especially where the cable is moving continuously while lifting While doing so look at the display to see if it reacts to the movements Potentiometer problem Move the board an...

Page 25: ...on If found heating the solder contacts can solve the problem Cables Bad connections cause changes when moving the scale Bend and move the cable briskly especially where the cable is moving continuous...

Page 26: ...er than the graduation For example Increments of 2 lb 0 91 kg graduation or 5 lb 2 26kg graduation HELP messages HELP 2 Scale is overloaded Take load from scale If there is no load do the same checks...

Page 27: ...Lift Rite Tel Toll Free from USA 1 800 558 6012 Greene NY 13778 Publication Number 1234959D 2022 Dated 14 Sep 2022 25 THIS PAGE LEFT BLANK INTENTIONALLY...

Page 28: ...Lift Rite Tel Toll Free from USA 1 800 558 6012 Greene NY 13778 Publication Number 1234959D 2022 Dated 14 Sep 2022 26 SPARE PARTS EXPLODED VIEW...

Page 29: ...Load Cell Calibration Board 1 11 990 1194 Indicator Housing Back Cover RAL 1028 1 12 990 1195 Indicator Housing Pedestal 1 13 990 1196 Battery Charger 1 14 990 1155 Bolt Forkshoe Mounting M12 x 60 1...

Page 30: ...ower percentage could mean the fork cover is not mounted When the zero point is defined the system automatically returns to the standard weighing mode Single Point Calibration Press the key for about...

Page 31: ...eys to change all the segments until the proper weight is entered Press the key to return to calibration mode The e1 pointer starts flashing Press the key for 3 seconds to confirm the entered weight T...

Page 32: ...segment starts flashing Use the and keys to change all segments until the proper weight is entered Press the key to return to calibration mode The e1 pointer starts flashing Press the key for 3 secon...

Page 33: ...n the P_01 with the right digit flashing At this stage you may proceed as follows Press the key quickly to enter parameter 01 The display shows the setting for this parameter at this moment You may ch...

Page 34: ...range 0 1 0 2 0 5 10 20 50 2 04 Number of graduations for every range 0000 9900 divisions 1000 05 Weighing capacity system full scale 0000 99999 units 5000 06 Motion tolerance for stable 0 32 1 off 0...

Page 35: ...tabits comport 1 7 8 8 22 Parity comport 1 none odd even none 23 Stopbits comport 1 1 2 1 24 Not used 25 Dataprotocol comport 1 0 4 0 0 PC bi directional command structure 1 not used 2 Remote display...

Page 36: ...switch off time 0 99 mins 2 0 not switched off 52 Auto shut off time if not used 0 99 mins 15 0 always on 53 Not used 54 Peak hold time 0 7 4 55 threshold value 9999kg lb 200 56 89 Not used 90 Reset t...

Page 37: ...d up to 120 US Labor charges may be reimbursed up to 60 US per unit per repair at the sole discretion of the manufacturer Transportation of the product to and from a LIFT RITE authorized dealer local...

Page 38: ...that each operator has successfully completed the training required by this paragraph l 1 ii Trainees may operate a powered industrial truck only under the direct supervision of persons who have the k...

Page 39: ...all not be permitted n 9 If at any time a powered industrial truck is found to be in need of repair defective or in any way unsafe the truck shall be taken out of service until it has been restored to...

Page 40: ...Lift Rite Tel Toll Free from USA 1 800 558 6012 Greene NY 13778 Publication Number 1234959D 2022 Dated 14 Sep 2022 Part Kit Number 1234962...

Reviews: