PARAMETER SETTINGS
ATTENTION: Before entering the setup mode, make sure that the battery sup-
ply is sufficient. A low battery may cause the micro-processor to block. If
this happens remove the empty battery and replace it with a fully charged
battery. You should be able to start the indicator in the normal way.
To enter the setup mode, turn on the indicator and keep the
key pressed for 20 seconds. You go
through the normal start-up routine (all segments on; software version; calibration number, and
weight) and end up in the “P_01” with the right digit flashing.
At this stage you may proceed as follows:
•
Press the
key quickly to enter parameter 01.
•
The display shows the setting for this parameter at this moment.
•
You may change the setting by using the
or the
key.
OR
•
You can accept the setting by pressing
.
OR
•
To move to the next parameter you press the
key.
OR
•
To move to the previous parameter you press the
key.
To leave the set-up mode, you do the following:
•
With “P_XX” in the display, press the
key quickly.
•
The display shows “P_00”.
•
Press the
key again quickly.
•
If a change was made to the settings, the display shows “SET__” briefly and then returns to
the normal weighing mode. The calibration number is increased every time a change is
made in the set up and also after a new calibration.
•
If no change was made, the display returns into the normal weighing mode.