Mains connection
Work on the electric installation may only be carried out by qualified electricians.
The mains power supply (main incoming line conductor) must be disconnectable at all poles by means of a mains
switch (in accordance with EN 60204-1 section 5.3).
Check that the mains voltage agrees with that specified on the type plate.
Connect mains current supply lines and control line according to wiring diagram (if the control cable is
not included in the delivery).
The L1, L2, L3 and PE terminals for the mains connection are located in the separate control box.
A cable 4G1.5² (minimum cross section 1.5 mm²) is necessary for the mains connection.
After connecting, press button for lifting. If the load moves downwards, interchange the L1 and L2
supply cores.
Disconnect mains supply before!
4.2
Electric connections for the pendant control
Connect the cable for the pendant control according to wiring diagram.
Figure 5: Control pendant
4.3
Electric limit switch for lifting
4.3.1
Layout
Figure 6: Electric limit switch for lifting
Caution!
The emergency limit switches should not be used under normal operation.
emergency stop
lifting
lowering
rope drum
actuator for electric limit switch for lifting
hook tackle