GARAGE DOOR OPERATOR
Photo beam connection (optional)
– Fig.15,Fig.16
Switch control connection (optional)
– Fig.15
Remark:
1.
Flash (Caution Light) Should be less than 25W.
2.
PB (External Push Button) Should be “ NO”.
This function can be applied to side hung doors.
After you set this function, the side hung doors will open outwards. When you open the door, the trolley will
move forward, when you close the door, the trolley will move backwards.
Figure 15
22
Programming Motor Reversal Function
a)
Press and hold
SET
Button until “1” appears on the display, next
press the UP button until “ ” appears on the display to enter this
function setting then release the button.
b)
Press the
SET
button again. The unit is now in the programming
motor reversal function mode.
c)
Press
UP / Down
button once to set the function.
You can choose “0” or “1”.
Figure “0”: The function is closed.
Figure “1”: The function is opened.
e)
Press
SET
button to confirm the settings and it will return to
standby status automatically and display “ll”.
NOTE:
The function is closed normally.
You need to reset the limits after you choose this function!
SET
UP
C
ODE
DOWN
SET
UP
C
ODE
DOWN
SET
UP
C
ODE
DOWN
TERMINAL INTRODUCTION & APPLICATION
SET
UP
C
ODE
DOWN