2.3
SETTING UP WITH A DMX512
CONTROLLER
2.3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING
(STAG MODE)
The figure above shows a simple DMX512
layout with the starting address of the first
unit set at 1, with the second set at 12 and
so on... (Note that when used in this way,
the CH11 ID function must be inactive (CH11=0))
DMX512
CONTROLLER
●
●
Each unit has 11 DMX channels so the DMX Addresses should increase by increments of
11 (e.g. 1,12,23,34...)
●
The ID address has not been set so therefore when using the controller CH11 must
be inactive ( CH11=0 ).
●
It is also possible to deactivate ID address selecting
【
ID OFF
】
from the
【
Settings
】
menu.
on the fixture
●
Each DMX Address may be used as many times as required.
●
Any DMX address in the range from 001 to 512 may be used.
Connect the DMX512 controller to the units in series.
2.3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAG MODE)
Connect the DMX512 controller to the units in series
●
Each unit has 11 DMX channels so the DMX Addresses should increase by increments of
11 (e.g. 1,12,23,34...)
●
Each DMX Address may be used as many times as required.
●
Any DMX address in the range from 001 to 512 may be used.
●
Each DMX address may carry up to 66 separate ID addresses.
●
【
ID
】
should be set in the menu on each unit in ascending values
(i.e. 1,2,3...)
●
【
ID On
】
should be set in the
【
Settings
】
menu on each unit.
●
ID addresses are accessible from Ch9 on the DMX512 controller.
●
Example:
6
............
DMX Addr.1
DMX Addr.12
DMX Addr.23