background image

LIGHT PROGRESS

 

        

UV-BOX-E3/40H-NX-R [Eng.] 

Revision 3 - October 2020 

 

Page 

10

 of 

16

 

 

 

TECHNICAL SPECIFICATIONS 

 

DIMENSIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 1: 

UV-BOX

 

E3/40H-NX-R 

  

LAMP LIFETIME (h)*

 

≤ 18.000 

  

  

SUGGESTED REPLACEMENT

 

Deduct 1 hour for every lighting (max. 2 Years). 

  

  

TOTAL CONSUMPTION (W)

 

120 

  

  

EXTERNAL DIM. AxBxC (mm.)

 

750 x 550 x 350 

   

  

INTERNAL DIM. DxExF (mm.)

 

600 x 500 x 310 

   

  

WEIGHT(Kg.)

 

22 

   
   

  

INOX SHELVES

 

  

  

 

SPARE PARTS 

  

UV LAMP CODE

 

n.3 CHS

-40WH 

   

   

 

  

BALLAST CODE

 

n.3 EB

-55P 

   
   

  

TIMER SWITCH CODE

 

n.1 PM

4HW-H-AC240V-J 

   
   

*

Continuous Operation 

 

  Highly efficient selection UV-C lamp (rating 253.7nm) pure quartz 

  Stainless Steel AISI 304 Cabinet with UV resistant polycarbonate window (LEXAN ®) 

  All materials are tested to resist UV-C rays  

  Plastic rack for foods material with 11-16 knife housings 

  Timer for treatment duration programming  

  Timer for a Pause between the two subsequent programs (irritations)  

  Safety switch to automatically turn off the UV light when the door is open  

  Electronic Ballast specific for ultraviolet UV-C (220-240V, 50-60Hz) CE Lamps  

  UVLON ® PIPE protection (optional) 

  Noise: <70dB(A) 

  Vibrations: <0.5 m/s

2

 

Summary of Contents for UV-BOX-E3/40H-NX-R

Page 1: ...IGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 1 of 16 UV BOX E3 40H NX R AISI 304 Stainless Steel Germicidal UV BOX with Direct Radiation for STERILISATION MODEL UV BOX E3 40H NX R...

Page 2: ...re that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine...

Page 3: ...must follow the device in case of passage of property and accompany the device until its disposal It s possible to contact Light Progress technical office to ask for updated instruction manuals and i...

Page 4: ...osed UV lamps turn on and begin the disinfection of the inside space and surfaces This will last for the whole programmed working time the possible opening of the door during the disinfection action i...

Page 5: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 5 of 16 DEVICE CODES...

Page 6: ...wo welded eyelets behind and at the top on the cabinet ELECTRICAL CONNECTION Make sure that the device will be installed where it will fit with the existing environmental conditions Before connecting...

Page 7: ...commend the bottom scale hrs hours Finally set the bottom scale of the central black quadrant by acting on the screw at the bottom on the left above the word OMRON We recommend the bottom scale 12 2 A...

Page 8: ...S UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 8 of 16 DISINFECTION TIMES FOR BACTERIA VIRUS AND YEASTS We suggest a treatment on both sides of the item 1 cycle then invert the item and start t...

Page 9: ...OUBLESHOOTING UV LAMP See MAINTENANCE POWER SUPPLY This model is supplied with electronic ballast that provides an emission 15 higher than traditional reactors and also the pipes are not affected by t...

Page 10: ...ER SWITCH CODE n 1 PM4HW H AC240V J Continuous Operation Highly efficient selection UV C lamp rating 253 7nm pure quartz Stainless Steel AISI 304 Cabinet with UV resistant polycarbonate window LEXAN A...

Page 11: ...ht Progress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personn...

Page 12: ...property due to failure to follow these instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits co...

Page 13: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 13 of 16...

Page 14: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 14 of 16 CIRCUIT DIAGRAM...

Page 15: ...___________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _____...

Page 16: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 16 of 16...