background image

 

LIGHT PROGRESS

 

UV-BOX-E3/40H-NX-R [Eng.] 

 

Revision 3 - October 2020 

 

 

Page 

4

 of 

16

 

 

 

DEVICE DESCRIPTION 

 

UV-BOX-E3/40H-NX-R 

has a stainless steel AISI 304 structure with 2 stainless steel AISI 304 flat grills to support the

 

objects  to  be  disinfected.  The  grids  support  the  stored  items  minimizing  dead  spots  and  achieving  disinfection  of 

99.99% in very short exposure times. 

 

The box is equipped with three UV-C 40 W lamps, protected by the grid to prevent hits and damages. The steel door is 

equipped with a transparent anti UV polycarbonate window and a position switch for turning off the UV lamps when the 

door is opened. 

 

The box is also equipped with a control panel which has an on/off switch and a timer 

Irradiation time can be adjusted from 1 second to 500 hours. 

 

APPLICATIONS AND RESULTS 

 

This cabinet can be used for germicidal disinfection and maintenance and sterility of objects and tools for healthcare, 

pharmaceutical labs, microbiological labs, food industries, etc. 

 

After washing, the objects can be stored inside the germicidal box, in order to maintain the condition of cleanliness 

in time; objects can thus be used with confidence, even after several hours after washing. 

 

 

UV-BOX-E3/40H-NX-R is among the few items on the market to offer extreme effectiveness, as it possesses three 

opposing lamps of high power (40W), which can radiate uniformly in all directions and directly on instruments 

surface. Furthermore, the internal reflection increases the amount of UV radiation which invests the instrumentation 

from all directions, reducing to zero the micro-shadows and lowering significantly the exposure times. 

Very short exposure times are thus obtained to get a 99.9% sterilization. 

 

OPERATION 

 

 

The switching on / off of the box is controlled by a programmable cycle of pause / working time intervals. 

 

You can decide on the duration of the irradiation and of the pause interval between two subsequent working periods. 

Whenever the door is closed, UV lamps turn on and begin the disinfection of the inside space and surfaces. This will 

last for the whole programmed working time; the possible opening of the door, during the disinfection action, 

immediately shuts off the lamps, in order to ensure personnel safety; if you will close the door again, a new disinfection 

action will begin from the start. At the end of the working period, the lamps will automatically switch off. At the end of 

the pause period, the lamps will automatically switch on. This sequence allows for the ability to maintain aseptic 

conditions even at distance in time. 

 

The duration of the working time and of the pause time is manually adjustable before the beginning of the treatment. 

 

BENEFITS AND ADVANTAGES 

 

 

A.  PHYSICAL ACTION AND ENVIRONMENTAL PROTECTION.  

Treatment by UV-C rays is purely physical, and always achieves the same response; also, there are no problems 

with overdose and rooms are always safe and practicable (when devices are turned off).  

Rather, many methods of chemical treatment involve the use of dangerous products for the environment, and 

are difficult to biodegrade, as well as the risk of contamination of foodstuffs. Also, the use of chemicals is likely 

to develop resistant microbial forms with consequent danger to human health. 

 

B.  IMMEDIATE EFFECT.  

It takes just a very short time to obtain effective results (99% killing of the bacteria). 

 

C.  PRACTICABILITY AND SAVINGS.  

The treatment is immediate and ready for use. The maintenance is minimal with low costs of both energy 

consumption and repairs. 

 

D.  NO CONTRAINDICATION FOR EQUIPMENT TO BE TREATED.  

This device provides the ability to maintain a sterile equipment, without the slightest contraindication. Equipment 

to be disinfected, or previously sterilized, can be preserved for a long time and are ready  for use, since the 

treatment is dry and without heat generation. 

 

E.  TOTAL SAFETY.  

Ultraviolet rays are confined inside the enclosure and cannot exit due to the UV ray’s resistant polycarbonate 

(LEXAN ®) and the micro-switches that prevent UV irradiation when the door is open. Therefore, it may treat the 

instruments in the presence of the operators. 

Summary of Contents for UV-BOX-E3/40H-NX-R

Page 1: ...IGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 1 of 16 UV BOX E3 40H NX R AISI 304 Stainless Steel Germicidal UV BOX with Direct Radiation for STERILISATION MODEL UV BOX E3 40H NX R...

Page 2: ...re that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine...

Page 3: ...must follow the device in case of passage of property and accompany the device until its disposal It s possible to contact Light Progress technical office to ask for updated instruction manuals and i...

Page 4: ...osed UV lamps turn on and begin the disinfection of the inside space and surfaces This will last for the whole programmed working time the possible opening of the door during the disinfection action i...

Page 5: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 5 of 16 DEVICE CODES...

Page 6: ...wo welded eyelets behind and at the top on the cabinet ELECTRICAL CONNECTION Make sure that the device will be installed where it will fit with the existing environmental conditions Before connecting...

Page 7: ...commend the bottom scale hrs hours Finally set the bottom scale of the central black quadrant by acting on the screw at the bottom on the left above the word OMRON We recommend the bottom scale 12 2 A...

Page 8: ...S UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 8 of 16 DISINFECTION TIMES FOR BACTERIA VIRUS AND YEASTS We suggest a treatment on both sides of the item 1 cycle then invert the item and start t...

Page 9: ...OUBLESHOOTING UV LAMP See MAINTENANCE POWER SUPPLY This model is supplied with electronic ballast that provides an emission 15 higher than traditional reactors and also the pipes are not affected by t...

Page 10: ...ER SWITCH CODE n 1 PM4HW H AC240V J Continuous Operation Highly efficient selection UV C lamp rating 253 7nm pure quartz Stainless Steel AISI 304 Cabinet with UV resistant polycarbonate window LEXAN A...

Page 11: ...ht Progress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personn...

Page 12: ...property due to failure to follow these instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits co...

Page 13: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 13 of 16...

Page 14: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 14 of 16 CIRCUIT DIAGRAM...

Page 15: ...___________________________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _____...

Page 16: ...LIGHT PROGRESS UV BOX E3 40H NX R Eng Revision 3 October 2020 Page 16 of 16...

Reviews: