background image

LIGHT PROGRESS

 

DIRECT-H-NX [Eng.]

 

Rev. 3 Eng. Oct 2020 

Pag. 4/16

 

 

 
 

 

DEVICE DESCRIPTION

 

 

UV-DIRECT ....H-NX 

series includes a UV-C lamp lodged inside a shaped case of small size, entirely made of stain- 

less  steel  and  with  polished aluminum screen, to  increase performance also reflecting the  proportion of  UV-C which 

should  be  dispersed  in  the  direction  opposite  to  that  useful.  The  UV-C  lamps,  with  emission  peak  at  235.7nm. 

(nanometers), have a strong germicidal power against all organisms (fungi, bacteria and viruses). 

The shaped case consists of a box of stainless steel AISI 304, within which a watertight Aluminum channel is located 

containing all the electronic power supply, with degree of protection IP 55. 

 

The UV-C lamp can also be protected by a grid of stainless steel AISI 304  (option). The unit comes complete with a 

cable 3x1 mm, without plug for power supply. 

 

OPERATION

 

 

The UV-DIRECT series can be installed in any type of environment to obtain deep disinfection of air and surfaces, even 

those that are difficult to reach with traditional cleaning systems. When the  lamp is ON there is a strong reduction of 

microbes present in the ambient air and on the surfaces reached by UV rays. For example, 8 mins. at a distance of 3m 

from  the  device,  there  is  a  99%  reduction  of  bacteria  Bacillus,  Coli,  Clostridium,  Legionella,  Vibrio,  Salmonella, 

Pseudomonas, Staphylococcus, Streptococcus, etc. 

 

Thanks to the natural circulation of the air, even the microbes located in hidden areas are continuously pulled toward 

the area of the U.V. rays so that their overall level decreases progressively. 

 

Use is allowed when there is no personnel present or if contained within adequately screened areas. The device must 

be switched on for 2 ± 3 hours during the hours of work breaks; for example, by means of a programming clock, night 

operation  can  be  managed  in  the  hours  immediately prior  to  the  entry  of  the  operators, to  allow  entry  in  a  freshly 

disinfected  site.  Operation  can  also  be  managed  by  means  of  appropriate  power  units  that,  especially  in  case  of 

installation of various devices, can manage other operations, such as: 

 

 

Power timing

; it is possible to regulate the duration of treatment by means of a regulatable timer. 

 

Managing entries

; a security system turns out the lights in case of entry of staff. 

 

Remote and local alarms 

in case one or more lamps switch off, due to wear, a spy light will light up on the front 

panel and it will be possible to use a contact to signal the failure remotely. 

 

Counter 

to manage the proper replacement of lamps. 

 

BENEFITS AND ADVANTAGES

 

 

DEEP AND CONTINUOUS

 

DISINFECTION

  

This device can be switched on continuously without people being present (i.e. during the night for 2-3 hours). The dis- 

infection of the air, the machinery, and everything that is contained inside the room allows beginning the work day in 

ideal hygienic conditions. In this way, the level of microbial load in one site is maintained constantly low. 

 

PHYSICAL ACTION AND ECOLOGICAL PROTECTION  

Treatment with UV-C rays is purely physical, always allowing treatment with the same efficiency; there is no danger of 

overdosing with UV rays in the air. In contrast, many chemical treatment methods involve the use of products that are 

risky and difficult to biodegrade, with consequent hazards to human health; besides, the use of chemical products, in 

contrast to UV-C rays, could develop resistant microbial forms. 

 

PRACTICALITY AND ECONOMY  

Treatment is immediate and ready to use. Maintenance is minimal with low costs of both energy consumption and of 

maintenance. 

 

IMMEDIATE EFFECT 

Effective treatment (99.9% bacteria reduction) takes just a few minutes. 

 

NO CHEMICAL/PHYSICAL CHANGES  

Treatment is cold and dry; it causes no organoleptic or qualitative changes in the food. 

 

NO DANGER OF DISPERSION OF GLASS  

With the special UVLON® protection, there is no danger of dispersion of glass fragments resulting from any breakage 

of UV-C lamps. 

Summary of Contents for UV-DIRECT NX Series

Page 1: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 1 16 INSTRUCTION UV DIRECT NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H H NX UV DIRECT E75H H NX...

Page 2: ...ance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper re...

Page 3: ...ction manual must be preserved and must always be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not...

Page 4: ...ly prior to the entry of the operators to allow entry in a freshly disinfected site Operation can also be managed by means of appropriate power units that especially in case of installation of various...

Page 5: ...ackaging and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occu...

Page 6: ...its should be carried out so as to distribute them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on t...

Page 7: ...ss steel brackets supplied anchoring them to the ceiling by screw anchors 8 to 10 mm or by self tapping screws not supplied After inserting the anchors onto the ceiling you should tighten by supplied...

Page 8: ...spersed ELECTRICAL CONNECTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that th...

Page 9: ...PV Multi pole plug and socket Wire Meaning Black wire for LED terminal n 1 Wire n 1 1 anode LED for synoptic 2 cathode LED MASTER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase...

Page 10: ...s on the lamp housing and let them slide along the lamp grab the lamp at the 2 ends and pull it in a direction parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING U...

Page 11: ...T Code n 1 EB 55P n 1 EB 55P continuous operation Selective UV C lamp at 253 7 nm with high efficiency lighting Body in Stainless Steel AISI 304 All the used materials are tested for resistance to int...

Page 12: ...rogress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personnel F...

Page 13: ...ese instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits component parts lists instructions for...

Page 14: ...f Machinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1...

Page 15: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 15 16 Notes...

Page 16: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 16 16...

Page 17: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 17 16...

Reviews:

Related manuals for UV-DIRECT NX Series