background image

LIGHT PROGRESS

 

DIRECT-H-NX [Eng.]

 

Rev. 3 Eng. Oct 2020 

Pag. 9/16

 

 

 
 

 

► UV-DIRECT-EL

 

In model 

-EL

 you get the possibility to remote control the functionality of UV lamp. 

Connected to the device there is a cable with 6 poles: a couple of poles carrying output signal to turn on LED indicating 

the UV lamp (when it’s lighting); another couple of poles triggers a voltage-free contact to be activated when a  lamp 

stops working (alarm function: open contact if  at  least one  lamp  UV  is  not working); in  addition, there are two input 

wires to power the device (phase and neutral). 

The faulty lamp alarm contact can be powered by max. 500mA of current and 24V of tension, and can be connected to 

an electronic panel as "MASTER-ST” control unit. 

For these models see the numbering of the wires on the table below. 

 

 
 
 

 
 
 
 

Model 

-EL  

Model 

-EL....-PV

 

 

 

 
 
 

 
 
 
 

 
 
 

 
 

In the device

 

UV-DIRECT-EL ….(-PV)

 

Multi-pole plug 

and socket

 

 

Wire

 

 

Meaning 

Black 

wire for LED 

terminal n° 

1

 

Wire 

n°1

 

1- 

anode LED 

for synoptic 

2- 

cathode LED 

MASTER-ST...... 

Red 

wire for LED 

terminal n° 

2

 

Wire 

n°2

 

Power line 230V-50Hz - phase 

terminal n° 

3

 

Wire 

n°3

 

3- 

Line 230V-50Hz (Phase) 

Power line 230V-50Hz - Neutral 

terminal n° 

4

 

Wire 

n°4

 

4- 

Line 230V-50Hz (Neutral) 

Electrical ground 

terminal n° 

9

 

Wire 

Y/G

 

Y/G- 

Ground terminal 

 

Alarm board faulty lamp 

terminal n° 

5

 

Wire 

n°5

 

5-6- 

open contact = faulty lamp 

(free contact without tension, max 500 mA-24V) 

terminal n° 

6

 

Wire 

n°6

 

 

► UV-DIRECT-EL …/…-PV

 

In 

–EL…PV

 version, in addition to the remote control described above, there is a socket/plug with multiple poles. This 

feature is useful when you need to separate the device form the cable in case of maintenance. 

The connection is easy and without mistakes thank to the forced insertion mechanism. 

 

 

Step 1

 

MULTI-POLE SOCKET AND PLUG

 

 

Step 2

 

 

APPROACH THE PLUG TO THE SOCKET. 

 

ROTATE THE LOCKING NUT OF HALF TURN. 

 

 
 
 
 
 
 

 
 

TURN THE PLUG WITH RESPECT TO THE SOCKET UNTILL 

THEY MATCH, AND THEN DEEPLY INSERT. 

Summary of Contents for UV-DIRECT NX Series

Page 1: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 1 16 INSTRUCTION UV DIRECT NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H H NX UV DIRECT E75H H NX...

Page 2: ...ance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper re...

Page 3: ...ction manual must be preserved and must always be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not...

Page 4: ...ly prior to the entry of the operators to allow entry in a freshly disinfected site Operation can also be managed by means of appropriate power units that especially in case of installation of various...

Page 5: ...ackaging and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occu...

Page 6: ...its should be carried out so as to distribute them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on t...

Page 7: ...ss steel brackets supplied anchoring them to the ceiling by screw anchors 8 to 10 mm or by self tapping screws not supplied After inserting the anchors onto the ceiling you should tighten by supplied...

Page 8: ...spersed ELECTRICAL CONNECTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that th...

Page 9: ...PV Multi pole plug and socket Wire Meaning Black wire for LED terminal n 1 Wire n 1 1 anode LED for synoptic 2 cathode LED MASTER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase...

Page 10: ...s on the lamp housing and let them slide along the lamp grab the lamp at the 2 ends and pull it in a direction parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING U...

Page 11: ...T Code n 1 EB 55P n 1 EB 55P continuous operation Selective UV C lamp at 253 7 nm with high efficiency lighting Body in Stainless Steel AISI 304 All the used materials are tested for resistance to int...

Page 12: ...rogress Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personnel F...

Page 13: ...ese instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits component parts lists instructions for...

Page 14: ...f Machinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1...

Page 15: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 15 16 Notes...

Page 16: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 16 16...

Page 17: ...LIGHT PROGRESS DIRECT H NX Eng Rev 3 Eng Oct 2020 Pag 17 16...

Reviews: