DECLARATION OF COMPLIANCE

 

 

We, LIGHT PROGRESS S.r.l., hereby declare under our own responsibility that the following units of own production: 

 

 
 

UV-FLOW….C-NX series

 

 

 

 

are in accordance with EEC directive 2014/30/EU (Electromagnetic Compatibility) 

 

are in accordance with EEC Machinery Directive dispositions 2006/42/EU 

 

are in accordance with EEC Low Voltage Directive 2014/35/EU 

 

are in accordance with EEC (RoHS) 2011/65/EU (D.Lgs 4 Marzo 2014, n.27) 

 

TECHNICAL STANDARDS APPLIED

 

 

UNI EN ISO 12100:2010

  Safety of Machinery - Basic Concepts, General Principles for Design - Risk 

assessment and risk reduction 

UNI EN ISO 13857:2008

  Safety of Machinery - Safety Distances to prevent danger zones being reached 

by the upper and lower limbs (2008) 

ISO 14120:2015

 

Safety of Machinery - Guards - General Requirements for the Design and 

construction of fixed and movable guards 

UNI EN ISO 13849-1:2016

 

Safety of Machinery - Parts of the Control System related to the Safety – Part 1: 

General Design Principles 

UNI EN ISO 14119:2013

  Safety of Machinery - Interlocking devices associated with guards - Principles for 

design and selection 

CEI EN 60204-1/2016

 

Safety of Machinery - Electrical Equipment of Machines. Part 1: General Rules 

(2010) 

EN 61439-1:2011

 

Low-voltage Switchgear and Control Gear Assemblies. Part 1: General rules 

 

FURTHER TECHNICAL STANDARDS APPLIED:

 

 

IEC EN 60335-1 "Safety of household electrical appliances and similar” 

Electronic Ballasts for the control of the lamps in accordance with the standard EN 60928. 

Germicidal UV-C Lamps in accordance with EN 61199. 

Electrical Protective Measures in accordance with IEC 70-1, EN 60229. 

 

Anghiari, 8.14.2020 

 

 

 
 

 

 

 

Responsible for Standards:  Dr. Aldo Santi 

 
 

 
 
 

 
 
 
 
 
 
 
 
 

LIGHT PROGRESS S.r.l. Loc. San Lorenzo,40 - 52031 ANGHIARI (AR) - ITALY - 

http://www.lightprogress.com

 

Summary of Contents for UV-FLOW C-NX Series

Page 1: ...LIGHT PROGRESS FLOW C NX Eng Rev 2 Oct 2020 Pag 1 16 UV FLOW C NX UV C Device with Controlled vertical horizontal Flow for Barriers against Germs MODELS UV FLOW E40H C NX UV FLOW E75H C NX...

Page 2: ...LIGHT PROGRESS FLOW C NX Eng Rev 2 Oct 2020 Pag 2 16...

Page 3: ...s switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask for genuine parts Improper repairs...

Page 4: ...must be preserved and must always be kept available for consultation it must follow the device in case of transfer of ownership and accompany the device until its disposal DISPOSAL Do not dispose of t...

Page 5: ...led contamination rooms clean rooms with air flow directed downwards This arrangement generates a vertical air flow which produces a barrier against germs pic 2 For proper use you should create a deco...

Page 6: ...kaging and please be careful not to damage the contents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occurre...

Page 7: ...e the floor In this way the flow will be slightly upwards which makes possible the continuous disinfection of the air circulating within the room because of the natural convective motions To cover you...

Page 8: ...de and about 1 5 to 2 meters deep Of course the doors should be normally closed preferably equipped with electrical or mechanical locking spring return type Normally only one port at a time must be op...

Page 9: ...ls this device by following these instructions the electrical scheme and the CEI norms Be sure that the device is installed where it will fit with the existing environmental conditions Before connecti...

Page 10: ...can be powered by max 500mA of current and 24V of tension and can be connected to an electronic panel as the MASTER ST control unit For the EL models refer to the numbering of the wires on the table...

Page 11: ...degrees Loosen the nuts of the holder and slide them along the lamp grab the lamp from the 2 ends and pull it in a di rection parallel to the unit Repeat steps in reverse to reassemble the new lamp a...

Page 12: ...ode complete n 1 CpE 40H n 1 CpE 75H continuous operation TECHNICAL FEATURES Highly efficient selective UV C lamp at 253 7 nm pure quartz Stainless steel AISI 304 body All used materials are tested to...

Page 13: ...ess Damages caused by modification of device system without Light Progress previous consent Improper use of the product falling or crashes Modifications or repairs made by unauthorized personnel For d...

Page 14: ...instructions We recommend you to carefully read all the given instructions The manufacturer agrees with the buyer to provide upon request schemes of circuits component parts lists instructions for ca...

Page 15: ...chinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 Gen...

Page 16: ...LIGHT PROGRESS FLOW C NX Eng Rev 2 Oct 2020 Pag 16 16 Notes...

Page 17: ...LIGHT PROGRESS FLOW C NX Eng Rev 2 Oct 2020 Pag 17 16...

Page 18: ...LIGHT PROGRESS FLOW C NX Eng Rev 2 Oct 2020 Pag 18 16...

Reviews: