background image

C34

C42

INSTRUCTION

 

MANUAL

LED Profile

Please read these instruction manual  carefully before use

FLY DRAGON LIGHTING EQUIPMENT CO., LTD

Summary of Contents for LED Profile C34

Page 1: ... C34 C42 INSTRUCTION MANUAL LED Profile Please read these instruction manual carefully before use FLY DRAGON LIGHTING EQUIPMENT CO LTD ...

Page 2: ...und or parts are missing please contact our customer support team for further instructions Inside the box you should find the fixture a DMX XLR cable a power cable and this user manual INDEX 1 1 Safety information 2 2 Skill specifications and Performance trait 3 3 Photometric data 4 4 Control panel 6 5 Dimensional drawings 7 6 Component name 7 7 Lens tube 8 8 Install fixture 8 9 Mounting and insta...

Page 3: ...to the electricity mains must be carried out by a qualified electrical installer Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to connect to the electricity line in order to avoid overloading Don t use...

Page 4: ...mer 65536 class dimmer Total Lumen C34 6800LM C42 8800LM Luminance Efficiency C34 34 C42 42 Control Mode DMX512 Channel 11CH 1CH Mode 2CH Mode HSI 6CH HSI 7 13CH HSIC 7CH HSIC 7 14CH Studio 6CH Light size 725 305 482MM Single carton size 340 290 745MM LED Profile N W 7 3KG G W 9 5KG Four carton size 710 610 775MM N W 29 2KG G W 40 7KG Single carton size 340 290 380MM Lens tube N W 2 4KG G W 3 5KG ...

Page 5: ... 2 3 3 5 1 2 3 3 5 0 19 1 2 3 4 5 1 2 3 4 5 276 26 26 2 56 5 242 22 21 2 17 2 123 12 1 25 2 108 10 9 1 8 1 11 430 43 4 83 8 370 34 32 3 26 2 40 185 18 2 35 3 156 14 14 1 12 1 17 615 57 5 115 11 540 50 45 4 40 4 57 276 28 3 56 5 250 23 21 2 18 2 26 4 PHOTOMETRIC DATA C42 lens 36 C42 lens 26 C42 lens 19 White Red Orange Light green Green Blue red White Red Orange Light green Green Blue red White Red...

Page 6: ...2 2 5 0 1 2 3 3 5 1 2 3 3 5 0 19 1 2 3 4 5 1 2 3 4 5 224 24 2 44 4 187 17 16 2 16 2 21 102 11 1 21 2 84 8 7 1 7 1 9 330 34 3 64 6 270 25 23 2 21 2 31 149 16 1 30 3 122 11 11 1 9 1 14 480 54 5 98 9 406 38 35 3 33 3 45 224 24 2 44 4 185 17 16 2 15 2 21 5 White Red Orange Light green Green Blue red White Red Orange Light green Green Blue red White Red Orange Light green Green Blue red Distance m ft i...

Page 7: ...CONTROL PANEL 3 5 DMX POWER IN POWER OUT Keypad 3 5 DMX LCD PUSH PUSH MENU UP DOWN ENTER IN OUT IN DMX OUT POWER IN OUT 6 ...

Page 8: ...DIMENSIONAL DRAWINGS COMPONENT NAME 725 482 Yoke knob Accessory retainer Lens tube Slicing 305 Yoke looking knob 7 ...

Page 9: ...LENS TUBE INSTALL FIXTURE Screw Step 1 Slide the lens into the shutter barrel Step 2 Tighten the lens focus screw General use position Low clearance position 8 ...

Page 10: ...ne knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet cautton Be sure a ...

Page 11: ...eventually connect the last device s output all the devices are together as the following figure The devices control signal output or input by using the 3 5 pin XLR pug and socket If need to long then the communication cable please make sure the both side of 3 5 pin plug is one to one one to one two to two three to three Otherwise the communication cable will be interrupted PUSH PUSH MENU UP DOWN ...

Page 12: ...ease make sure the both side of 3 or 5 pin plug is one to one one to one two to two three to three Otherwise the communication cable will be interrupted The communicate cable is 2 cord screened cable 75Ω resistance with each core is at least a 0 5mm diameter Caution All the inside leading wire of 3 or 5 pin XLR plug couldn t touch each other or plinth Recommend to use the DMX signal terminator for...

Page 13: ...P DOWN ENTER Channel mode Standard 11CH HSI 6CH HSI 7 13CH HSIC 7CH HSIC 7 14CH Studio 6CH When PLUS 6CH is ON the display board channel shows 7CH Plus 6CH xx OFF ON PLUS 6CH only with HIS HISC two Channel Model 12 DMX Address Settings 1CH Mode xxxxx MENU SETTING 2800K 3000K 3200K 3500K 4000K 4500K 5000K 5500K 6000K 6500K 7000K 7500K 8000K 9000K 10000K 1CH Mode 1CH Mode 2CH Mode LED ON XX OFF ON 1...

Page 14: ...Status No Action Action Dimmer 0 100 CTO Settings CTO presets 2800K 3000K 3200K 3500K 4000K 4500K 5000K 5500K 6000K 6500K 7000K 7500K 8000K 9000K 10000K 13 ...

Page 15: ...sets 14 Settings Status Dimmer 0 100 No Action Action Colour Red Red orange Orange Yellow orange Yellow Yellow green Green Blue green Blue Blue purple Purple Red purple Dim Cur Standard Incandescent Linear Quick ...

Page 16: ... Macro 0 255 9 Dimmer 0 255 10 Dimmer fine 0 255 11 Strobe 0 255 Settings Fan mode Slow Fast Auto Power Protected Regulated Boost Language 语言 English 英文 Chinese 中文 BackLight Open Auto close 15S Reversal Normal Rota 180 Channel control 15 Specific Channel would be displayed according to your choice Backlight blink OFF ON ...

Page 17: ...eed DMX live 1 Red 2 Red orange 3 Green mint 4 Green 5 Blue 6 Indigo 7 CCT 8 Colour Macro 9 Dimmer 10 Dimmer fine 11 Strobe System version DIS Board V Service Time clean Developer Factory Error list Defualt Input Input Input 16 Specific Channel would be displayed according to your choice ...

Page 18: ...00 0 100 0 100 NO function 2800K From 2800K to 3000K 3000K From 3000K to 3200K 3200K From 3200K to 3500K 3500K From 3500K to 4000K 4000K From 4000K to 4500K 4500K From 4500K to 5000K 5000K From 5000K to 5500K 5500K From 5500K to 6000K 0 1 18 1 57 2 35 2 75 8 24 8 63 9 41 9 80 15 29 15 69 16 47 16 86 22 35 22 75 23 53 23 92 29 41 29 80 30 59 30 98 36 47 36 86 37 65 38 04 43 53 43 92 44 71 45 10 50 ...

Page 19: ...0K 8 9 Colour Macro Dimmer 10 Dimmer fine 11 Strobe 180 249 250 255 Slow closing fast opening slow fast Fast closing slow opening slow fast Slow closing slow open slow fast Random strobe slow fast Synchronous strobe slow fast NO function NO function 18 255 10000K 65 10 65 88 66 27 71 76 72 16 72 94 73 33 78 82 79 22 80 00 80 39 85 88 86 27 87 06 87 45 92 94 93 33 94 12 94 51 99 61 100 0 3 53 3 92 ...

Page 20: ...1 1 2 0 255 0 255 0 255 19 0 100 0 100 0 100 Dimmer Dimmer CCT 1CH Mode FUNCTION FUNCTION CHANNEL CHANNEL DMX VALUE DMX VALUE 2CH Mode ...

Page 21: ...128 129 255 0 50 2 50 59 100 Disable plus 6 Enable plus 6 8 9 10 11 12 13 0 255 0 255 0 255 0 255 0 100 0 100 0 100 0 100 0 255 0 255 0 100 0 100 Red Red orange Green mint Green Blue Indigo Only PLUS 6CH is ON 7 to 13 CH work 6CH FUNCTION CHANNEL DMX VALUE Strobe Slow closing fast opening slow fast Fast closing slow opening slow fast Slow closing slow open slow fast Random strobe slow fast Synchro...

Page 22: ... 79 93 94 96 0 1 18 1 57 2 35 2 75 8 24 8 63 9 41 9 80 15 29 15 69 16 47 16 86 22 35 22 75 23 53 23 92 29 41 29 80 30 59 30 98 36 47 36 86 37 65 CCT FUNCTION CHANNEL DMX VALUE Slow closing fast opening slow fast Fast closing slow opening slow fast Slow closing slow open slow fast Random strobe slow fast Synchronous strobe slow fast NO function NO function NO function 2500K From 2500K to 2800K 2800...

Page 23: ...237 238 240 241 251 252 254 100 255 8 0 128 129 255 0 50 2 50 59 100 9 10 11 12 13 14 0 255 0 255 0 255 0 255 0 100 0 100 0 100 0 100 0 255 0 255 0 100 0 100 6CH FUNCTION CHANNEL DMX VALUE From 4000K to 4500K 4500K From 4500K to 5000K 5000K From 5000K to 5500K 5500K From 5500K to 6000K 6500K From 6500K to 7000K 7000K From 7000K to 7500K 7500K From 7500K to 8000K 8000K From 8000K to 9000K 9000K 100...

Page 24: ...5 29 46 67 47 06 70 20 0 9 10 49 50 89 90 119 120 179 5 70 59 97 65 98 04 100 180 249 250 255 6 NC FUNCTION CHANNEL DMX VALUE Strobe Slow closing fast opening slow fast Fast closing slow opening slow fast Slow closing slow open slow fast Random strobe slow fast Synchronous strobe slow fast NO function NO function ...

Page 25: ...ING DIAGRAM AC100 240V 50 60Hz Switched power supply Power board LED Drive board Display board Power adapter 24 L N PE Input N L G 12V 48V GND GND Radiation board GND 48V J1 J3 J1 J2 12V GND GND 48V J7 J2 J4 J5 J1 J2 ...

Page 26: ...ion option are correct 2 Please check whether the communicate control cable is on good connection or the cable is too long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipment is mutually conjugate 5 Please arrange the wire well shorter the signal cable put ...

Page 27: ...e 3 Please disconnect the power supply when begin to maintenance take down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged or looseness must change a lamp or fix the lamp in order to avoid the accident 1 In order to ensure the projector could work normall...

Page 28: ... china com E Mail flydragon lightsky com cn lightsky08 vip 163 com flydragon lightsky china com lightsky01 vip 163 com lightsky china vip 163 com flydragon vip 163 com 13829779791 vip 163 com Add No 51 Yunfeng Rd Xinhua Industrial Zone Huadu District Guangzhou City China ...

Reviews: