INSTALLATION INSTRUCTIONS

For Flex II

 300 Watt Magnetic

 Transformer - Wall 

_________________

tel.800-670-8137  www. lightwavesconcept .com

Light Waves

LED Waves

Light Waves

Lighting SuperStore

_________________

tel.800-670-8137  www. lightwavesconcept .com

SAVE THESE INSTRUCTIONS

 

AND REFER TO THEM WHEN ADDITIONS 

TO OR CHANGES IN THE TRACK CONFIGURATION ARE MADE.

_________________

tel.800-670-8137  www. lightwavesconcept .com

Trobleshooting

Did the breaker on the transformer trip?

•  If powering the system with more than one feed, make sure isolating connectors are separating each feed
•  Check that none of the elements are generating a direct short. If any elements have been shortened, check the FreeJack connector
•  Check the low-voltage side of the transformer with a voltmeter to ensure voltage does not exceed 12 or 24 volts

Is an individual element not working?

•  Check that the lamp is installed securely
•  Check the lamp to see if it has burned out
•  Check the FreeJack connector for proper contact

Did the breaker on the main panel trip?

•  Make sure the circuit has not been overloaded
•  Change the breaker in the panel to an inductive load breaker

Is the system still not working?  Why not try checking the basics?

•  Check the light switch (or cord switch on a plug-in transformer)
•  Make sure the power feeds from the transformer to the rail are tightly connected
•  Check for loose wire nuts in the junction box, canopy, or transformer cover
•  Make sure the transformer’s 120 volt side is wired correctly

Dimming Issues

•  There are two kinds of low voltage dimmers. If you  wish to attach a dimmer to your Flex II system, make sure to use the correct ver-
sion: a magnetic dimmer should only be used with a magnetic  transofrmer. Likewise,  an electronic dimmer should only be used with 
an electronic transformer. Using the wrong dimmer will substantially shorten transformer life.
•  The dimmer should be placed on the input line  BEFORE the transformer.

Reducing Dimmer Noise

Dimmers can generate a buzzing noise that some people may find disturbing. To reduce buzzing, we recommend:
•  using the dimmer type compatible with the transformer;
•  adding debuzzing dimmer coil in series. This coil is included with all our magnetic surface transformers;
•  Loading the system to at least 80 % of capacity. For example, a 300 watt transformer should have at least 240 watt load. 