3
8. Схема установки прожектора
(для внутреннего освещения)
Рис.7
Рис.7а
Рис.7б
0,5 м
min 3
м
9. Схема электрических соединений
LLC "Lighting technologies production"
UM SPORT series floodlight projector
CERTIFICATE
1. Designation
1.1. The floodlight projector is designed for architectural lighting, exposure lighting, lighting of sports fields, halls, etc. and suitable for use in 220 VAC (380 VAC
– for floodlights with capacity of
2 kW)
(±10%), 50 Hz (±0,4 Hz). Electric power quality shall be in accordance with GOST 13109-97.
1.2. The floodlight meets the safety requirements of GOST R 60598-2-5-99 IEC, GOST R IEC 60598-1-2003, and EMC GOST R 51318.15-99.
1.3. The floodlight can be used for both outdoor and indoor installation.
2. Specifications
2.1. Electric shock protection class of the floodlight
– I according to GOST R IEC 60598-1.
2.2. Environmental exposure protection level for the floodlight is IP66, for the remote unit
– IP 66 according to GOST 14254-96.
2.3. Climatic version and location category is Clm App1 according to GOST 15150-69.
2.4. Power factor is min. 0.85. For ECG lighting fixtures, power factor is min. 0.95
2.5. The cable gland bush sleeve allows the input of 3-core power cable with an outer diameter of 9-12 mm.
3. Delivery set
Floodlight, pcs.
1
Remote unit (with the electronic control gear)
1
Package, pcs.
2
Data Sheet, pcs.
1
4. Safety requirements
4.1. Perform installation, cleaning of the floodlight and replacement of components (lamps) only with power off.
4.2. Fixing of the floodlight on the supporting surface shall be made in compliance with the distances indicated in the diagram.
4.3. Under the conditions of Clause 4.2, the floodlight can be installed on the surface made of normally combustible material.
4.4. Do not open the floodlight during operation or if it is not cooled down.