ON
OFF
Each dimmer channel (non-dim) is switched
off until DMX Level 127
. On the
DMX
Level 128
the dimmer will
interconnect
. The dimmer will be used as NON dim. The
dimmer will switch like a standard I/O Switch.
On channel bundle 3 x 600 W all dip switches are connected. At this case you have
to put at least one dip switch on Position
ON
.
Normal dimmer function on each channel according to the dimmer curve.
DIP-Switch
1-6
DIP-Switch Settings
ON
OFF
Channel bundle activated: Channel 1,2 / Channel 3,4 / Channel 5,6 will be
connected each to one channel. Thereby, the max. work load will increase to
600 W
per bundle dimmer
. The channels have to connected simultaneously at the output.
Now,
3 DMX addresses
are in use.
Channel bundle is off. The dimmer is operating in the 6 channel mode with a
maximal work load of
300 W per output
. Now,
6 DMX addresses
are in use.
DIP-Switch
7
ON
OFF
Dimmer curve 2
Dimmer curve 1
DIP-Switch
8
1
2
3
4
5
6
7
8
9
10
ON
Channel 1
interconnect
at
DMX Level 128
Channel 2
interconnect
at
DMX Level 128
Channel 3
interconnect
at
DMX Level 128
Channel 4
interconnect
at
DMX Level 128
Channel 5
interconnect
at
DMX Level 128
Channel 6
interconnect
at
DMX Level 128
3 Channel modus
at 600 W
max. workload
dimmer curve
2
Auto Frequence
60 Hz
OFF
Channel 1
dims
between DMX-
Level
0-255
Channel 2
dims
between DMX-
Level
0-255
Channel 3
dims
between DMX-
Level
0-255
Channel 4
dims
between DMX-
Level
0-255
Channel 5
dims
between DMX-
Level
0-255
Channel 6
dims
between DMX-
Level
0-255
6 Channel modus
at 300 W
max. workload
dimmer curve
1
Fixed frequency
50 Hz
G