background image

 

 
 

 

 

ENGLISH 

Installation:

 

 
Be sure to check the unit for damage before using it. Optimally, use the original packaging or 

suitable transport or storage packaging to protect the product from dust, moisture, etc. when not 
in use. 

The unit can be installed upright or suspended. The device must always be attached to a solid, 

approved carrier or a suitable surface. The opening in the product bracket must be used to fasten 
the device. Always provide a second, independent safety device for the device, e.g. a safety 

device.  
 

WARNING! (Risk of injury due to falling down) 

It must be ensured that the installation of the device complies with all legal standards and 

regulations in the respective country of use. It must be ensured that the device is always 
secured by a second fastening (e.g. Safety). 

 

NOTE! (Risk of overheating) 

The max. permissible ambient temperature of this device is 40° C.   
Make sure that the device is always adequately ventilated. 

 
NOTE! (Using tripods) 

As soon as the unit is mounted on a tripod, it must always be ensured that it stands 

securely and securely. Make sure that the maximum permissible load capacity of your 
tripods is not exceeded. 

 

NOTE! (Error during data transmission) 

Never connect the DMX input or output to audio devices such as power amplifiers or 
mixing consoles!  

DMX cables enable trouble-free operation and the highest possible transmission reliability 
of signal data. Do not use a microphone cable. 

 
 

 

Commissioning: 

 

Connect the product to the power supply and then turn it on. Wait until the heating element has 

reached the operating temperature. The control is now either via DMX, remote control or via 
operation on the device itself. 

 

It is imperative that you ensure that all cables used for commissioning (power and control) are 
subject to the applicable regulations and are undamaged. Place the product in a safe, ventilated 

place.  
 

Ensure that untrained personnel do not have access to the product. Maintain a minimum distance 
of 50 cm from walls and only operate the fog machine on suitable, non-combustible surfaces. 

When installing on trusses, always use a safety rope that complies with the regulations and 
approved sling material. 

 

 

 
 

Summary of Contents for LIG0015924-000

Page 1: ...e place the device in a well ventilated place out of the reach of flammable materials or liquids Do not cover any ventilation openings as this may result in overheating Please disconnect the power plug if the unit is not to be used for a long period of time or if maintenance work is to be carried out The device is designed for a maximum ambient temperature of 40 Celsius The device should not be in...

Page 2: ...9 221 8884 0 Fax 49 221 8884 2500 info musicstore de Intended use The product LightmaXX Vector Fog 1 5 is used exclusively for the generation of artificial fog by vaporizing the filled fog fume The device may only be used for this purpose and in accordance with the operating instructions Other purposes as well as operation under other operating conditions are expressly not intended and can lead to...

Page 3: ...R Electric shock caused by short circuit Modifications to the power cord or plug are prohibited Failure to do so may result in fire or death due to electric shock NOTE Fire hazard Ensure that the unit is not exposed to a direct source of heat and is used away from open fire Never cover or tape any ventilation slits or the device itself NOTE Operating conditions Due to its structural characteristic...

Page 4: ...unted on a tripod it must always be ensured that it stands securely and securely Make sure that the maximum permissible load capacity of your tripods is not exceeded NOTE Error during data transmission Never connect the DMX input or output to audio devices such as power amplifiers or mixing consoles DMX cables enable trouble free operation and the highest possible transmission reliability of signa...

Page 5: ...2 This machine only works with the B key c CH3 This machine only works with the C key d CH4 This machine only works with the D key The machine is turned on after pressing the selected button for 3 seconds After pressing the button again for 3 seconds the function is switched off 3 OFF DMX operation Configuration of the DMX connector Resistance 120 ohm 1 4w between pin 2 DMX and pin 3 DMX of the la...

Page 6: ...06 255 1 100 FOG OUTPUT No Description No Description 1 Fluid tank 8 ON OFF switch 2 Tank cap 9 Fuse 3 Mounting bracket 10 Power cord 4 Locking screw 11 Control Panel 5 Carrying handle 12 DMX in output 3 pin 6 Tank indicator 13 Receiver remote control 7 Nozzle for fog output ...

Page 7: ... 5 Power supply AC 220 240V 50Hz Power consumption 1500 Watt Power connections PowerCon compatible Heating time approx 3 5 min Fluid consumption max 350 ml min Tank 2 5 Liter Output range approx 6 m DMX connector 3 pin DMX 1 channel mode Remote control Yes funk Dimensions without bracket W x D x H 58 x 24 5 x 13 5 mm Weight 7 4 Kg Symptom Troubleshooting No function Check the mains connection and ...

Page 8: ...educe the burden of packaging to a minimum The use of environmentally friendly and recyclable materials is always of elementary importance Please complete the packaging after use to the appropriate recyclings Disposal of packaging Ensure that paper packaging plastic material etc are recycled separately Observe the labels and the corresponding regulations Disposal of batteries Batteries do not belo...

Page 9: ...ENGLISH MS ID LIG0015924 000 01 2019 Notes ...

Reviews: