background image

4

Front View

Fan Grill

0

3

 Sanitizer

Control Setting

On/Off
Ionization
Fan Speed

Part

Control for the negative ion generator is separate from the activated oxygen control. Negative ions
can be created around the clock to keep down dust and particulate.

Ozone or activated oxygen is normally kept at modest levels in occupied spaces.  To remove heavy
odors, the units may be adjusted to a higher level for a period of time.  Some use a timer to
completely deodorize the home or office while away.  Unused O

3

 reverts back to O

2

 in about an hour.

Dual Ion
Emitters

Ionizer ON/OFF
& Fan Speed

On/Off activates the unit and turns on the Ionic
Purifier it also controls the fan speed.

Activates the ozonator and adjusts by square footage
of treatment area.  The unit should be adjusted
according to size of treatment area and sensitivities.

Removable fan grill.  May be wash with warm soapy
 water.  Dry completely before replacing.
(Unplug unit before removing)

Fan Grill

0

3

 Sanitizer

Square Feet

Function

Summary of Contents for LA-2SP

Page 1: ...1 UserGuide Model LA 2SP Air Purification Unit Bring Freshness Indoors ...

Page 2: ...ION ATTENTION RISK OF ELECTRICAL SHOCK DO NOT OPEN Caution TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE BACK COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVCE PERSONNEL Contents Quick Start 3 Features of the Model LA 2SP 4 Operation Installation 6 Determine Your Square Footage 7 Using a Timer 8 Where to Use 8 Service 8 Warranty 8 Cleaning Maintenance 9 Troubleshoot...

Page 3: ... space to be treated Turn Sanitizer dial on and select square feet setting Vacate the space for 1 to 4 hours de pending upon the severity of the odors Return to space turn Sanitizer dial off open doors and outside windows until sanitizing smell is gone Warning Excess ozone O3 concentrations can cause mucous membrane and respiratory irritation If you detect the sanitizing smell when you walk into t...

Page 4: ...r level for a period of time Some use a timer to completely deodorize the home or office while away Unused O3 reverts back to O2 in about an hour Dual Ion Emitters Ionizer ON OFF Fan Speed On Off activates the unit and turns on the Ionic Purifier it also controls the fan speed Activates the ozonator and adjusts by square footage of treatment area The unit should be adjusted according to size of tr...

Page 5: ... and removal of ceramic plates for cleaning Removable ceramic plate Wash with warm soapy water Rinse and dry completely before replacing Houses removable fuse Spare fuse included 1 amp 1 25 inch 110 Volt grounded cord unless otherwise specified DO NOT bypass ground Allows for easy moving from one room to another Ceramic Plate Power Cord Plate receiver slot Fuse Holder Convenient Handle Handle ...

Page 6: ...environmental conditions such as altitude humidity air movement severity of existing odors house design and square footage If you desire to treat the entire home with the same level of ozone set the fan switch on your home s heating cooling system to the ON position rather than AUTO Open all interior doors and adjust the activated oxygen level to the appropri ate square footage Then place the unit...

Page 7: ...rent areas of your home or office The concentration of ozone will be higher in the immediate area of the unit Example To determine the total square feet of area to be treated 15 20 15 20 20 300 Square Feet 400 Square Feet 375 Square Feet 500 Square Feet 25 40 600 Square Feet 800 Square Feet 300 400 600 800 2 100 square feet 375 500 875 square feet Warning Excessive ozone concentrations may cause m...

Page 8: ...2 8200 as listed on he back panel of the unit Non U S customers send fax to 850 893 2594 for instructions Your air unit comes with a 3 year limited warranty from the date of original pur chase Refer to enclosed warranty card for complete details Please complete and return the warranty registration card within ten days of date of purchase in order to activate your warranty Homes living areas High p...

Page 9: ...y looking for two pieces of wire Take a q tip or cotton swab dipped in alcohol and clean any dirt that may have accumulated on the needlepoints This process may be done when plates are being cleaned While you have the front grill cover off the unit you may also clean the fan and the grill itself To clean the fan simply wipe the blades with a damp cloth or vacuum The grill cover may also be cleaned...

Page 10: ...ponse to the hydrocarbons The level of ozone in some cities may exceed 200 parts per billion ppb on days when pollution is high On the other hand without O3 and UV light the earth would be an odorous place with mold mildew and viruses running rampant The forces of nature are designed to keep the outdoors clean and healthy Unfortunately there is normally very little ozone in our indoor spaces where...

Page 11: ... agencies Each home is different so it requires a trial and error process to locate the right setting on the dial If you choose to use the O3 Sanitizer in occupied spaces set the ozonator dial at a modest level initially and let it run for a couple of hours If you smell ozone when you walk into the room turn the dial down or off On the other hand if you smell household odors turn the dial slightly...