Performance Recessed CFL Downlighting

  1101HLIE

Page 2 of 2 

6 ¾" Aperture Horizontal Lensed, Compact Fluorescent, Performance Series, 

 

Integrated Emergency, Reflector Trim

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B0908

Lightolier is a Philips group brand

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 54  54  54  54  53  53  51  51  49  49  46
1 51  50  49  47  49  47  47  45  45  44  42
2 48  46  43  41  45  41  43  40  42  39  38
3 45  42  39  37  41  36  40  36  39  35  34
4 42  38  35  33  38  33  36  32  36 32  31
5 40  35  32  29  34  29  34  29  33  29  28
6 37  32  29  27  32  27  31  26  30  26  25
7 35  30  27  24  29  24  29  24  28  24  23
8 33  28  24  22  27  24  22  27  22  26  21
9 31  26  23  20  25  20  25  20  25  20  19

10 29  24  21  19 24  19  23  19  23  19  18

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 33.0

32W TRIPLE TUBE LAMP

, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS

181

363

544

725

   0

195

390

585

780

 

60˚

30˚

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 63 63  63  63  61  61  59  59  56  56  53
1 59  58  56  55  56  55  52  52  51 51  48
2 56  52  50  48  52  49  50  46 48  45  43
3 52  48  45  42  47  44  46  41 44  40 39
4 49  44 40  37  43  40  42  37  41  36  35
5 45  40  36  33  39  36  38  33  37  33 31
6 42  37  33  30  36  33  35  30  35  30  29
7 40  34  30  27  33  30  33  27  32  27  26
8 37  31  28  25  31  27  30  25  30  25  24
9 35  29  25  23  29  25 28  23  28  23  22

10 33  27  23  21  27  23  26  21  26  21 20

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 35

CANDLEPOWER SUMMARY

Angle

0˚ CP

777 

763 

10 

734 

15

688 

20 

644 

25 

582 

30 

490 

35 

432 

40 

386 

45 

359 

50 

231 

55 

113 

60 

30 

65 

70 

75

80 

85 

90 

ZONAL LUMEN SUMMARY

    Zone

Lumens

0-10

72.01

10-20

198.72

20-30

275.06

30-40

272.29

40-50

232.89

50-60

96.02

60-70

10.23

70-80

2.99

80-90

2.08

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens

%Lamp

%Fixt

**  Efficiency = 52.7%  ** 

0-30 545.79 

24.8 

47

0-40 818.08 

37.2 

70.4

0-60 1146.99 

52.1 

98.7

0-90 1162.29 

52.8 

100

90-120

0

90-150

0

90-180

0

0-180

0

SC = 1.1

CERTIFIED TEST REPORT NO. 3352FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

32W TRIPLE TUBE LAMP

, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS

150

2

1

300

450

600

   0

186

371

557

742

 

1 – 90°

 

2 – 0°

60˚

30˚

SC = 1.00 x 1.02

CERTIFIED TEST REPORT NO. 3359FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

ZONAL LUMEN SUMMARY

    Zone

Lumens

0-10

68.88

10-20

192.34

20-30

245.08

30-40

221.66

40-50

168.88

50-60

90.1

60-70

14.8

70-80

3.09

80-90

2.18

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

CANDLEPOWER SUMMARY

Angle

0˚ CP

90˚ CP

715 

 715

712 

730

10 

694 

 742

15

652

701

20 

598 

631

25 

520 

544

30 

440 

437

35 

365 

330

40 

299 

244

45 

242 

198

50 

185 

159

55 

105 

94

60 

42 

41

65 

9

70 

4

75

3

80 

2

85 

2

90 

2

181

363

544

725

   0

143

287

430

573

60˚

30˚

SC = 1.2

CERTIFIED TEST REPORT NO. 3351FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**

32W TRIPLE TUBE LAMP

, LUMEN RATING = 2200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0

55  55  55  55  53  53  51  51  49  49  46

1

52  50  49  47  49  47  47  45  45  44  42

2

48  45  43  41  44  41  43  40  42  39  37

3

45  41  38  36  40  36  39  35  38  34  33

4

42 37  34  32  37  31  36  31  35  31  30

5

39 34  31  28  34  28  33  28  32  28  26

6

36  31  28  25  31  25  30  25  29  25  24

7

34  29  25  23  28  23  28  23  27  22  21

8

32  26  23  21  26  21  25  20  25  20  19

9

30  24  21  19  24  19  24  19  23  19  18

10 28  23  19  17  22  17  22  17  22  17  16

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 35.0

ZONAL LUMEN SUMMARY

    Zone

Lumens

0-10

54.19

10-20

153.56

20-30

223.16

30-40

245.6

40-50

211.31

50-60

105.76

60-70

13.51

70-80

2.57

80-90

2.22

90-100

0

100-110

0

110-120

0

120-130

0

130-140

0

140-150

0

150-160

0

160-170

0

170-180

0

0-30

506.3 

23 

50.3

0-40

727.96 

33.1 

72.3

0-60

986.94 

44.9 

98

0-90 1007.01 

45.8 

100

90-120

0

90-150

0

90-180

0

0-180 1007.01 

45.8 

100

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens

%Lamp

%Fixt

**  Efficiency = 45.8%  ** 

0-30

430.92 

19.6 

42.6

0-40

676.51 

30.8 

66.9

0-60

993.57 

45.2 

98.2

0-90 1011.87 

46 

100

90-120

0

90-150

0

90-180

0

0-180 1011.87 

46 

100

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens

%Lamp

%Fixt

**  Efficiency = 46%  ** 

CANDLEPOWER SUMMARY

Angle

0˚ CP

573 

571 

10 

564 

15

549 

20 

524 

25 

491 

30 

448 

35 

398 

40 

339 

45 

278 

50 

210 

55 

113 

60 

39 

65 

70 

75

2

80 

85 

90 