background image

Lighting Systems

 

Baselyte-BSL10

Page 3 of 4    

 Light T5 HO Wall Mount Direct/Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Wiring Options: 1 Circuit

1 Circuit with Emergency Circuit/Night Light (EC/NL)

One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal 
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.

Type 3: 

cct. w/EC/NL

All lamps wired on one circuit.

1 Circuit

Type 5: 

Chloride standard  

CTP700

Type M

: Bodine standard 

 LP550

Type E: 

Chloride high performance 

CTP300

Type P: 

Bodine high performance  

LP600

All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected 
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by 
installer. Leads for both normal circuit and battery pack are wired to fixture ends.

1 Circuit with Emergency Battery Pack (EM)

One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery 
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together 
or wire separately if controlled independently. Leads for normal circuit, EC/NL circuit and EM wired 
to fixture ends. All lamps in EC/NL section to be wired together. 

1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack

Type J: 

Chloride standard  

CTP700

%#.,

%-

%#.,%-

Type 1: 

cct.

Type 8:

 cct. w/cct. thru wire

Type H: 

cct. w/2cct. thru wire

Type 7: 

cct. w/dimming

Summary of Contents for Baselyte-BSL10

Page 1: ...2 module lengths or continuous rows 5 Ballasts electronic 120V or 277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Flexible mounting locations Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints Intersections Self aligning joining system with hands free pre joining wire access Labels ...

Page 2: ... 17 14 9 23 19 15 22 17 15 18 15 13 10 21 17 14 20 16 13 17 14 11 ZONAL LUMEN SUMMARY ZONE LUMENS BARE LAMP LUMINAIRE 0 90 90 180 0 180 2899 1599 1300 44 8 55 2 100 0 28 0 34 4 62 3 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY REFLECTANCE 80 70 50 WALL REFLECTANCE 50 30 10 50 30 10 50 30 10 0 66 66 66 60 60 60 50 50 50 1 57 55 53 52 50 49 44 42 41 2 50 46 43 46 43 40 38 36 34 3 44 40 36 40...

Page 3: ... high performance CTP1300 Type P Bodine high performance LP600 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by installer Leads for both normal circuit and battery pack are wired to fixture ends 1 Circuit with Emergency Battery Pack EM One 4 section in a one c...

Page 4: ... 4 sections with Emergency Battery Pack EM Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire Type S 2cct w 2cct thru wire 2 Circuit A B Switching alternate 4 sections with Emergency Circuit Night Light EC NL One 4 section in a two circuit fixture A B switching to be wired on a se...