Lighting Systems
Baselyte-BSL10
Page 3 of 4
Light T5 HO Wall Mount Direct/Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Wiring Options: 1 Circuit
1 Circuit with Emergency Circuit/Night Light (EC/NL)
One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal
circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.
Type 3:
cct. w/EC/NL
All lamps wired on one circuit.
1 Circuit
Type 5:
Chloride standard
CTP700
Type M
: Bodine standard
LP550
Type E:
Chloride high performance
CTP300
Type P:
Bodine high performance
LP600
All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected
to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by
installer. Leads for both normal circuit and battery pack are wired to fixture ends.
1 Circuit with Emergency Battery Pack (EM)
One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery
pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together
or wire separately if controlled independently. Leads for normal circuit, EC/NL circuit and EM wired
to fixture ends. All lamps in EC/NL section to be wired together.
1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack
Type J:
Chloride standard
CTP700
%#.,
%-
�
�
%#.,%-
Type 1:
cct.
Type 8:
cct. w/cct. thru wire
Type H:
cct. w/2cct. thru wire
Type 7:
cct. w/dimming