background image

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group • B0710

Vetro Architectural Decorative 

FP02

Page 2 of 2 

Pendant 

Catalog No. FP02/FP01, 32W Triple Tube, 2400 Lumens.

Catalog No. FP02/FP01, 26W Triple Tube, 1800 Lumens

Report No. 3095FR
SC = 2.0

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

140

95

123

5

157

100

122

10

194

105

119

15

232

110

116

20

256

115

112

25

267

120

106

30

265

125

99

35

254

130

92

40

235

135

84

45

212

140

75

50

190

145

66

55

175

150

57

60

163

155

47

65

153

160

37

70

146

165

26

75

139

170

14

80

133

175

5

85

127

180

2

90

122

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30 204.54

8.5

11.9

0-40 362.64

15.1

21.1

0-60 683.78

28.5

39.8

0-90 1121.98

46.7

65.3

90-120 370.57

15.4

21.6

90-130 459.74

19.2

26.7

90-150 566.71

23.6

26.7

90-180 597.18

54.9

34.7

0-180 1719.16

71.6

100

**  Efficiency = 71.6%  ** 

60°

30°

0

67

134

200

267

204

60°

30°

153

102

51

0

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

124

90

103

5

139

95

104

10

166

100

103

15

190

105

101

20

200

110

98

25

203

115

94

30

193

120

89

35

176

125

84

40

157

130

77

45

143

135

70

50

134

140

63

55

128

145

55

60

123

150

47

65

119

155

39

70

116

160

31

75

113

165

22

80

111

170

11

85

107

175

3

90

103

180

2

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

160.61

8.9

11.9

0-40

270.4

15

20

0-60

496.44

27.6

36.7

0-90

851.27

47.3

62.9

90-120

313.17

17.4

23.1

90-130

387.96

21.6

28.7

90-150

477.26

26.5

28.7

90-180

502.48

27.9

37.1

0-180 1353.75

75.2

100

**  Efficiency = 75.1%  ** 

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 83 83 83 83 78 78 68 68 59 59 47
1 73 68 64 60 64 57 55 50 48 43 34
2 65 58 52 47 54 45 47 39 40 34 26
3 59 50 44 38 47 36 41 32 35 28 21
4 54 44 37  32 41 30 36 27 31 23 18
5 49 39 32 27 37 26 32 23 27 20

15

6 45 35 28 23 33 22 29 20 25 17

13

7 42 31 25 20 30 19 26 17 22 15

11

8 39 28 22 18 27 17 23 15 20 13

10

36 26 20 16 24 24 15 22 13 19 12

9

10 34 24 18 14 22 13 20 12

17 11

8

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 29.0

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

14.08

10-20

53.67

20-30

92.85

30-40

109.8

40-50

111.18

50-60

114.85

60-70

118.45

70-80

119.92

80-90

116.46

90-100

113.2

100-110

109.73

110-120

93.24

120-130

74.79

130-140

54.55

140-150

34.75

150-160

18.27

160-170

6.37

170-180

.58

Report No. 3096FR
SC = .96

Catalog No. IP02/IP01 150W T-4, 950 Lumens.

60°

30°

0

240

180

120

60

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens %Lamp

%Fixt

0-30

170.48

6.1

12.2

0-40

263.56

9.4

18.8

0-60

467.85

16.7

33.4

0-90

838.84

 30

59.8

90-120

350.51

12.5

25

90-130

434.83

15.5

31

90-150

535.51

19.1

31

90-180

563.65

20.1

40.2

0-180 1402.49

50.1

100

**  Efficiency = 50.1%  ** 

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 55 55 55 55 51 51 38 44 38 38 30
1 48 45 42 40 42 37 31 32 31 28 21
2 43 38 34 31 36 29 26 25 26 22 16
3 39 33 29 25 31 24 22 21 22 18 13
4 35 29 25 21 27 20 20 17 20 15

11

5 33 26 21 18 24 17 18 15 18 13

9

6 30 23 19 15 22 15 16 13 16 11

8

7 28 21 17 13 20 13 15 11

15 10

7

8 26 19 15 12 18 11

13 10 13

9

6

9 24 17 13 11

16 10 15

9

12

8

6

10 22 16 12 10 15

9

14

8

11

7

5

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 150

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

21.93

10-20

64.18

20-30

84.37

30-40

93.08

40-50

94.43

50-60

106.86

60-70

118

70-80

125.89

80-90

127.1

90-100

126.29

100-110

119.43

110-120

104.78

120-130

84.33

130-140

61.35

140-150

39.33

150-160

20.57

160-170

6.98

170-180

.59

Report No. 3094FR

CANDLEPOWER SUMMARY

Angle Mean CP Angle Mean CP

0

229

95

116

5

226

100

115

10

236

105

113

15

234

110

110

20

204

115

106

25

183

120

100

30

165

125

94

35

148

130

87

40

135

135

79

45

125

140

71

50

121

145

62

55

119

150

53

60

118

155

44

65

119

160

34

70

119

165

24

75

119

170

12

80

119

175

3

85

116

180

1

90

115

ZONAL LUMEN SUMMARY

Zone

Lumens

0-10

16.16

10-20

65.89

20-30

122.49

30-40

158.1

40-50

163.81

50-60

157.34

60-70

152.38

70-80

147.13

80-90

138.68

90-100

133.65

100-110

126.18

110-120

110.74

120-130

89.16

130-140

65.13

140-150

41.84

150-160

22.03

160-170

7.67

170-180

.78

COEFFICIENTS OF UTILIZATION

Ceiling

80%

70% 

50%

30%

Wall

70 50 30 10 50 10 50 10 50 10

0

RCR

Zonal Cavity Method - Effective Floor Reflectance = 20%

Room 

Cavity 

Ratio

0 79 79 79 79 75 75 66 66 58 58 47
1 70 66 62 58 61 55 54 49 47 43 43
2 63 56 50 46 52 43 46 38 40 34 27
3 57 48 42 37 45 35 40 31 34 28 22
4 52 42 36 31 40 29 35 26 30 23 18
5 47 38 31 26 35 25 31 22 27 20 18
6 43 34 27 22 32 21 28 19 24 17

13

7 40 30 24 19 28 18 25 17 22 15

11

8 37 27 21 17 26 16 23 15 20 13

10

9 34 25 19 15 23 14 21 13 18 12

9

10 32 23 17 13 22 13 19 12

17 10

8

Determined In Accordance With Current IES Published Procedures

Luminaire Input Watts = 33.0

Reviews: