Lightolier
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
A0902
Section 5/Folio K35-15
Job Information
Type:
Options/accessories
Stem Sets:
1/2” diameter tubing, 18” long, chrome plated finish. Catalog
Number:
18048
.
Stem Extension Kit:
1/2" diameter tubing, 18” long, chrome plated finish
extension. Catalog Number:
18148
.
Single Cable and Canopy.
Catalog Number:
WC60
.
Single Cable, Straight Cord and Canopy.
Catalog Number:
WCC60
.
Single Cable, Coiled Cord and Canopy.
Catalog Number:
WCCC60
.
Electrical Wiring Options:
Consult factory.
Fusing:
Internal fast-blow fusing. Suffix:
GLR
.
Internal slow-blow fusing. Suffix:
GMF
.
Specifications
Performance:
In an installation of 2 lamp 32W Iuminaires with a room cavity ratio
of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall be not less
than .77. Candelas at 65° shall not exceed 66 (8 cell). To control veiling reflections,
Iuminaire output in the 30°- 90° zone shall be not less than 87.4%.
Materials: Chassis parts
are die-formed 20 gauge code cold rolled steel, End
caps are die-cast aluminum with soft rounded corners.
Specifications (continued)
Louver:
Pre-anodized aluminum (Coilzak
®
or equal).
Finish: Louver
–low iridescence semi-specular anodized aluminum (standard).
Chassis exterior
–semi-gloss (standard) flat acrylic-white baked enamel,
Cavity
–white baked enamel. Phosphate undercoating.
Electrical:
Thermally protected class “P” ballast, non PCB. If K.O. is within 3"
of ballast, use wire suitable for at least 90°.
Labels:
I.B.E.W./UL and ULc Listed.
LL
Lytecel
Linear:
Pendant
with 3”
Deep Parabolic
Precision
Contoured
Pre-Anodized
Aluminum Louver
Fixture
Length:
4
= Nominal 48"
8
= Nominal 96"
Number
of Cells:
8
= 1 row of 8
12
= 1 row of 12
(48” Length
)
X
Top
Reflector:
X
=None
Lamp
Quantity*
1
=1 Lamp
2
=2 Lamp
3
=3 Lamp
32
Lamp Type/
Fixture Length:
32
=T8
0
(Nominal 48")
Options:
Add appropriate
suffix to catalog
no, ie: (
GLR
)
Lytecel Linear
LL4MF8LX232
Page 2 of 2
Uplight/Downlight, Pendant, 4-5/8" Deep, 8-9/16" Wide,
48" or 96" Nominal Lengths
(Without End Caps)
, 2 Lamp T5
Model No. LL4MF8LX232120SO (8 Cell)
LER = FP - 70.9
IW - 58
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.38
Ordering Information
Explanation of Catalog Number. Example: LL4MF8LX232120SOGLR
Report Number: G2004161
Catalog Number: LL4MF8LX232120SO
Lamp: FP32/T8 TL841
Luminaire: LL4 with no reflector,
8 cell louver
Ballast: Triad B232IUNV-HP
67.0 Watts
Report is based on 2850 Lumens per lamp.
Efficiency: 82.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.9
Shielding Angles:
65
55
Plane:
0-Deg
90-Deg
Luminous Length:
48.000
6.480
0.0
45.0
90.0
FLUX
0
672
672
672
5
662
671
678
64
15
624
672
736
193
25
560
719
903
337
35
478
802
1068
493
45
369
754
846
515
55
208
408
335
307
65
33
65
50
66
75
13
13
0
11
15
85
5
6
4
6
90
3
4
4
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2362.
3740.
3424.
55
1581.
2214.
1414.
65
0
320.
0
403.
0
228.
75
0
182.
00
97.
00
56.
85
0
133.
00
59.
00
24.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 80 77 74 68 57 55 47 46 45
0
2 74 68 63 52 49 47 42 40 39
0
3 67 60 55 46 43 40 38 35 33
0
4 62 53 47 41 37 34 34 31 29
0
5 57 48 41 37 33 30 30 27 25
0
6 52 43 36 33 29 26 27 24 22
0
7 48 38 32 30 26 23 25 22 19
0
8 45 35 29 27 23 20 23 19 17
0
9 41 32 26 25 21 18 21 18 15
10 39 29 23 23 19 16 19 16 14
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
0
594
10.4
0
12.6
0
0-
0
40
1087
19.1
0
23.1
0
0-
0
60
1909
33.5
0
40.5
0
0-
0
90
1997
35.0
0
42.4
90-120
0
695
12.2
0
14.7
90-130
1212
21.3
0
25.7
90-150
2130
37.4
0
45.2
90-180
2718
47.7
0
57.6
0
0-180
4715
82.7
100.0
ZONAL LUMEN SUMMARY
Model No. LL4MF12LX232120SO (12 Cell)
LER = FP - 67.5
IW - 58
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.56
Report Number: G2004164
Catalog Number: LL4MF12LX232120SO
Lamp: F32/T8 TL841
Luminaire: LL4 with no reflector,
12 cell louver
Ballast: Triad B232IUNV-HP
67.0 Watts
Report is based on 2850 Lumens per lamp.
Efficiency: 79.2%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.1
1.9
Shielding Angles:
65
55
Plane:
0-Deg
90-Deg
Lumen Length:
48.000
6.480
0.0
45.0
90.0
FLUX
0
651
651
651
5
640
649
656
62
15
596
644
704
185
25
523
685
905
326
35
434
778
1074
477
45
318
689
854
478
55
83
274
291
212
65
25
33
32
37
75
10
12
9
12
85
5
5
4
6
90
4
4
4
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2037.
3417.
3456.
55
0
631.
1487.
1228.
65
0
243.
0
205.
0
146.
75
0
140.
00
90.
00
46.
85
0
133.
00
49.
00
24.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 76 73 71 55 53 52 44 43 42
0
2 70 65 60 49 46 44 39 38 36
0
3 64 57 52 44 40 38 35 33 31
0
4 59 51 45 39 35 33 32 29 27
0
5 54 46 40 35 31 28 29 26 24
0
6 50 41 35 32 28 25 26 23 21
0
7 46 37 31 29 25 22 24 21 18
0
8 43 33 28 26 22 19 21 19 16
0
9 40 30 25 24 20 17 20 17 15
10 37 28 22 22 18 15 18 15 13
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
0
572
10.0
0
12.7
0
0-
0
40
1049
18.4
0
23.2
0
0-
0
60
1740
30.5
0
38.5
0
0-
0
90
1795
31.5
0
39.8
90-120
0
695
12.2
0
15.4
90-130
1212
21.3
0
26.8
90-150
2130
37.4
0
47.2
90-180
2718
47.7
0
60.2
0
0-180
4513
79.2
100.0
ZONAL LUMEN SUMMARY
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T8
SO*
H
I
*
1-3 Lamp Elec. T8
O3*
H3*
1-4 Lamp Elec. T8
O4*
H4*
2-3 Lamp Elec. T8
O6*
H6*
LOL Dimming T8
PS
–
*Instant Start Standard
Body
Finish:
F
=White
B
=Black
Voltage:
120 or 277
UNV
= Universal
Voltage
120-277
Body Style:
M
= Individual
Module
J
= Joiner
Module
Louver Finish:
L
= Low Iridescence
Semi-specular
(standard)
P
= Low Iridescence
Specular
W
=White
*For any additional ballast or wiring combination consult factory.
*8' units have lamps in tandem.