background image

Paralyte 2448

PLA2G18LP332

Page 2 of 2

2' x 4' Recessed Fluorescent, 3-1/8" Deep, 18 Cell Parabolic Louver

Static and Air Return 3 Lamp, T8 or T12

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 2/Folio G50-63 Rev. A

Job Information

Type:

Options & Accessories

Prewiring:

3/8” factory prewired cable (three no. 18 AWG leads, 6’ long), 

Suffix: 

FF6

, (Four no. 18 AWG leads, 6’ long), Suffix: 

FF14

.

Fusing:

Internal fast-blow fusing. Suffix: 

GLR

.

Internal slow-blow fusing. Suffix: 

GMF

.

Fluorescent Emergency Lighting System:

Factory-installed emergency power

battery pack with charger and inverter, concealed in fixture channel. Operates one
fluorescent lamp at reduced light output for 90 minutes. Suffix: 

EM

Radio Interference Filter:

120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: 

R

. One per ballast. Suffix: 

B

.

Electrical Options:

Special wiring, fusing or dimming ballasts and installed

lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer:

If T-bar is less than 1-1/2” deep, order Catalog Number: 

STC

.

2 each end is required.

Specifications

Performance: 

In an installation of 3 lamp 32W Iuminaires in a room cavity ratio

of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be
less than 82. To prevent glare the VCP shall not be less than 74 either lengthwise
or crosswise (at 100fc level) and the average brightness at 65° shall not exceed
1645 candelas per square meter. To control veiling reflections, luminaire output in
the 3C°-90° zone shall not be less than 69.7%.

Specifications (continued)

Air Return:

Designed to provide optimum air return. Air is returned through the 

lamp compartment for all ceiling systems and direct to plenum through slots in
slot grid and narrow grid ceiling systems.

Materials: Chassis parts

are die-formed code gauge cold rolled steel. 

Housing

is embossed for rigidity with all edges turned up for safe handling. 

Louver

is

pre-anodized aluminum (Coilzak

®

or equal). 

Finish: Louver

–semi-specular anodized low iridescence, vertical grain reflector

sheet. 

Cavity

–white baked polyester minimum 86% reflectance. Phosphate

undercoating. 

Chassis exterior

–black baked polyester enamel.

Electrical:

Thermally protected class “P” ballast C.B.M. approved, non-PCB. If

K.O. is within 3” of ballast, use wire suitable for at least 90°.

Labels:

I.B.E.W./UL and ULc Listed.

Photometry

Model No. PLA2G18LP332120O3

coefficients of utilization — zonal cavity method  

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

84

82

79

77

75

73

74

72

71

2

78

73

68

69

65

62

66

63

61

3

72

65

59

61

57

53

59

56

53

4

66

58

52

55

50

46

53

49

46

5

61

52

45

49

44

40

48

43

40

6

56

47

40

45

39

35

43

39

35

7

52

42

36

41

35

31

39

35

31

8

48

38

32

37

32

28

36

31

28

9

45

35

29

34

29

25

33

28

25

10

42

32

27

31

26

23

31

26

23

visual comfort probability 

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

74

73

70

79

73

71

73

75

20

30

75

76

71

69

74

71

71

68

20

40

75

76

72

72

74

71

71

70

20

60

75

76

72

72

74

72

71

70

30

20

74

77

71

77

74

76

73

74

30

30

75

79

73

67

74

76

72

67

30

40

75

77

73

71

74

76

72

69

30

60

75

78

73

71

74

76

73

70

30

80

75

78

73

71

74

76

73

70

40

20

75

77

74

78

74

76

77

75

40

30

75

77

76

68

74

76

76

67

40

40

75

78

77

72

74

76

76

70

40

60

75

76

77

72

74

76

76

71

40

80

75

76

76

72

74

75

76

71

40

100

75

76

76

72

75

75

76

71

60

30

75

78

76

71

74

76

76

70

60

40

75

76

77

73

74

76

76

72

60

60

75

76

76

74

74

75

75

73

60

80

75

76

76

74

75

75

75

73

60

100

76

76

76

74

75

75

75

73

100

40

75

76

75

74

74

75

76

73

100

60

76

76

76

74

75

75

75

73

100

80

76

76

76

74

75

75

75

73

100

100

76

76

76

74

75

75

75

73

room cavity ratio

luminaries lengthwise

luminaries crosswise

LER=FP-67.2   IW - 85   BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens=$3.57

PL

Paralyte

2448:

3-1/8" Deep

Parabolic
Precision

Contoured

Pre-anodized

Aluminum

Louver

A

2

Fixture 

Width

G

Ceiling Type:

G

=Grid (lay-in T bar)

18

Louver Finish:

L

= Low Iridescence

Semi-Specular (standard)

W

= White Paint

Lamp

Quantity:

3 or 4 Lamps

Lamp/

Fixture Length:

32

=T8

34

=T12

(Nominal 48")

Voltage:

120 or 277

Ballast Type:

1 & 2 Lamp Mag. T12

LE

<

20THD

<

10THD

1 & 2 Lamp Elec. T8

SO*

H

I

*

1–3 Lamp Elec. T8

O3*

H3*

1–4 Lamp Elec. T8

O4*

H4*

LOL T8 Dimming

PS

*

*Instant Start Standard

Options:

Add appropriate
suffix to catalog

no., ie: (GLR)

Other dimming options. Consult factory.

Number of

Cells

Ballast Cover:

P

= Dual V Reflector

S

= Single V Reflector

(4 lamp -

S

Reflector only)

G98032
PLA2G18LP332120O3

Body Style:

A

= Air Handling

/Static

Ordering Information

Explanation of Catalog Number. Example: PLA2G18LP332120O3GLR