VR PARABOLIC
VRA1G12LS132
Page 2 of 2
1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 2/Folio G05-37 REV. A
Job Information
Type:
PHOTOMETRY
MODEL NO. VRA1G12LS132120SO
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
69
67
65
63
61
60
61
59
58
2
64
61
58
58
55
53
56
54
52
3
60
55
51
52
49
47
51
48
46
4
56
50
45
48
44
41
46
43
41
5
51
45
40
43
39
36
42
38
36
6
47
40
36
39
35
32
38
34
32
7
44
36
31
35
31
28
34
30
28
8
40
32
27
31
27
24
30
27
24
9
37
29
24
28
23
20
27
23
20
10
34
26
21
25
21
18
24
21
18
visual comfort probability
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
95
94
92
88
90
85
81
80
20
30
96
94
93
90
90
88
82
77
20
40
96
95
93
92
90
88
83
79
20
60
96
95
94
92
90
88
84
79
30
20
95
94
92
87
90
87
85
82
30
30
96
95
94
89
90
89
85
79
30
40
96
95
94
91
90
88
86
80
30
60
97
96
95
91
91
88
86
80
30
90
97
96
95
91
91
88
86
80
40
20
95
95
93
88
90
87
85
84
40
30
96
95
94
90
90
88
86
82
40
40
97
95
94
91
91
88
87
82
40
60
97
96
95
91
91
88
87
82
40
80
97
96
95
91
91
88
87
83
40
100
97
96
95
91
91
88
87
83
60
30
96
95
94
91
91
88
86
82
60
40
97
96
94
92
91
88
87
83
60
60
97
96
95
92
91
89
87
83
60
80
97
96
95
92
91
89
87
83
60
100
97
96
95
92
91
89
87
83
100
40
97
95
94
92
91
88
87
83
100
60
97
96
95
92
91
89
87
83
100
80
97
96
95
92
91
89
87
83
100
100
97
96
95
92
91
89
87
83
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example:VRA1G12LS132120SOGLR
VR
VR:
3" Deep
Pre-
anodized
Aluminum
Louver
for normal
VDT use
BLANK
= Standard
N
= NYC Code
BODY STYLE:
A=
Air Handling
S
=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G
= Grid (lay-in T bar)
F
=Flanged (overlap)
Z spline and
plaster frame
T
=Slot grid or
two-directional
concealed T
(see options)
12
NUMBER OF
CELLS:
1 row of
12 cells
LOUVER
FINISH:
L
=Low
Iridescence
Semi-specular
(standard)
P
=Low
iridescence
specular
S
SINGLE
WHITE
REFLECTOR
1
LAMP
QUANTITY
LAMP/
FIXTURE
LENGTH:
32
=T8
34
=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
1 Lamp Mag. T12
LE
<
20THD
<
10THD
1 Lamp Elec. T8
SO*
H
I
*
LOL Dimming
PS
–
*
Instant Start Standard
Other dimming options, consult factory.
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 50.1
IW - 30.6
BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.80
OPTIONS & ACCESSORIES
ACCESS PLATE:
Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa-
rately. Order Catalog Number:
ACP CSP
.
ELECTRICAL WIRING OPTIONS:
Consult factory.
FUSING:
Internal fast-blow fusing. SUFFIX:
GLR
.
Internal slow-blow fusing. SUFFIX:
GMF
.
RADIO INTERFERENCE FILTER:
120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX:
RF
.
CONTINUOUS ROW INSTALLATION:
For F type fixtures, half-width flanges are
required between fixtures. Order Catalog Number:
1FCTRIM
(each joint).
SPLAY TRIM:
For T ceiling type only. SUFFIX:
CTZ14 S2 SPLAY TRIM
.
AIR CLOSURE STRIP:
SUFFIX
ACS4
(factory installed).
DRYWALL KIT:
Order Catalog Number:
FK91X4
. Request Folio OA30-10.
CHICAGO PLENUM:
SUFFIX:
CP
.
SPECIFICATIONS
PERFORMANCE:
In an installation of 1 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .67 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To
meet IES RP-1 recommended (basic) requirements for VDT areas the VCP (visual
comfort probability) shall not be less than 91 either crosswise or lengthwise and
the maximum average brightness at 65°, 75° and 85° shall not exceed 837, 82 and
41 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes.
Candelas at Nadir (0°) not to exceed 652.
SPECIFICATIONS (continued)
AIR HANDLING:
(VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts
are die-formed embossed cold rolled steel.
Housing
is embossed for rigidity with all edges turned-in for safe handling.
LOUVER:
Pre-anodized aluminum (Coilzak@ or equal).
FINISH: Louver
—low iridescence semi-specular anodized vertical grain alu-
minum reflector sheet is standard.
Reflector
—white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Chassis exterior
—black
baked polyester enamel.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and C-UL.