Networking, Power and Service Connections
Page 46
Recommended: 48 Vdc surge protector
e.g.
Transtector DCOD 48-2.5
Indoor/Outdoor 48 Vdc Power Supply
110-240 Vac
Figure 3-4: Direct 48 Vdc Power Connection
To prevent damage to the building power infrastructure from potential
lightning strikes we recommend using an external 48Vdc Surge Protector as
shown in Chapter 1.2.4.2.
3.3
GROUNDING/ LIGHTNING PROTECTION
Ground the radio housing by attaching an AWG 14 solid copper wire to the ground pillar on the back
of the housing (see Fig. 3-5) and using the self-tapping screw and the wire lug provided with the
system. Attach the opposite end of the wire to the mounting pole and make sure that there is a good
and solid electrical contact. Most important, verify that the mounting pole is connected to the
building/tower grounding infrastructure.
Figure 3-5: Enclosure Ground Connection
Summary of Contents for AireLink 60
Page 1: ...LightPointe AireLink 60 Installation and User Manual...
Page 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Page 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Page 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Page 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Page 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Page 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Page 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Page 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Page 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Page 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...