AireLink
60 Installation and User Manual Rev. D
Networking, Power and Service Connections
Page 49
3.5
OUT-OF-BAND MANAGEMENT CONNECTION
The AireLink™60 Out-of-Band management connection shares the RJ45 100/1000Base-TX PoE
powering port provided via a CAT5/6 twisted pair Ethernet cable. To get access to the AireLink™
management system the input port of the PoE module must be connected to your management
network.
The Ethernet cable length of the management cable from the AireLink™ 60 radio to the switch or router
should not exceed 100 meters due to Ethernet compliance issues. Otherwise a suitable Ethernet
repeating device as shown in Chapter 1.2.4.3 must be used.
In Chapter 4 the AireLink™ Manager will be described in more detail.
3.6
CONSOLE PORT
The user panel micro USB based Console port is used to establish a serial port connection to a PC/laptop
and the shipment contains a micro USB2.0 cable to establish the connection. The serial port is used
by customer support personal / technicians for advanced troubleshooting purposes. It is therefore not
necessary to pull cable for the serial port during installation. All setup and management functions can
be performed over the AireLink™ Manager web-console, Telnet or SNMP. Before accessing the serial
connection the user/installer needs to download and install the appropriate USB to UART Bridge Virtual
COM
Port
(VCP)
drivers
from
the
Silicon
Labs
webpage
at
http://wwwqa.silabs.com/products/mcu/Pages/usbtouartbridgevcpdrivers.aspx. After installation of
the driver the serial port is accessible via a serial port communications program such as HyperTerminal
or PuTTY.
3.7
RSSI VOLTAGE CONNECTOR
The RSSI voltage level can be measured by connecting a digital voltmeter to the two pin and IP67
outdoor rated RSSI signal connector located on the outside of the radio enclosure (see Fig. 3-9). Two
adapter cables to connect the RSSI signals to a standard voltmeter equipped with banana plug
receptacles are included with the shipment (see Fig. 1-10). During the alignment process the RSSI
voltage readings are taken to achieve optimum alignment of the AireLink™ system.
RSSI Voltage Connector
Figure 3-9: RSSI Voltage Port Connector Location
Summary of Contents for AireLink 60
Page 1: ...LightPointe AireLink 60 Installation and User Manual...
Page 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Page 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Page 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Page 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Page 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Page 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Page 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Page 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Page 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Page 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...