2.10.2. Rear view of DVI-TP-TX200DL
Local Monitor Output
CATx outputs
+5V DC
Monitor Output
Connect one dual link DVI-D or DVI-I cable (only digital pins are
connected internally) between DVI-TP-TX200DL and local
display device. For lower resolutions, with a maximum pixel
clock frequency of 165 MHz, a single link cable can be used.
For more information, see chapter 2.7.
The output connector is able to supply 500 mA current on
pin 14 to power fiber optical DVI extenders like DVI-OPT-
TX100.
If a long DVI cable is connected then equalization and
reclocking may be necessary at the receiver end of the cable.
CAT A-B Outputs
Connect two CAT5, CAT5e, CAT6a or CAT7 (recommended)
cables between DVI-TP-TX200DL and the receiver (DVI-TP-
RX100DL or Lightware Hybrid Matrix equipped with dual link
twisted pair input cards).
If a lower resolution image is transmitted, with a maximum pixel
clock frequency of 165 MHz, then only one CATx cable needs
to be connected to CAT-A output.
Accidental connection of the CAT-A output of the DVI-TP-
TX200DL to the CAT-B input of a Lightware dual link twisted
pair receiver (and vice versa) does not result in damage to the
unit but it may result in faulty behavior. Please turn off the
devices, disconnect the cables and connect the cables to the
appropriate connectors.
The DVI-TP-TX200DL does not have networking capabilities.
Do not connect the RJ45 output of the DVI-TP-TX200DL to a
Local Area Network device or a PC. Doing so may damage the
unit!
+5V DC connector
Connect the output of the supplied +5V power adaptor.
CAUTION! Warranty void if damage occurs due to use of a