ISG Allegro LightWise USB 3.0 Technical Manual Version 1.3.1
30
7.
Trigger/Strobe Control
Trigger/Strobe Control Input/Output Connector
Connector Information:
On Camera: Hirose R10A-10R-12SB(71) - J1
Mating Plug (For Cables): Hirose HR10A-10P-12P(73)
Pin
Assignment
J1.1
Reserved do not attach
J1.2
Reserved do not attach
J1.3
Reserved do not attach
J1.4
Reserved do not attach
J1.5
STROBE 2 (OPTO ISOLATED)
J1.6
USER GROUND – FOR TRIGGER (OPTO ISOLATED)
J1.7
TRIGGER (OPTO ISOLATED)
J1.8
USER VCC 5-24V-FOR STROBES (OPTO ISOLATED)
J1.9
Reserved do not attach
J1.10
STROBE 1 (OPTO ISOLATED)
J1.11
Reserved do not attach
J1.12
Optional Shield / Chassis
Camera Trigger Details
The external interface consists of one isolated programmable Trigger Input and two isolated programmable
Strobe outputs.
1.
Trigger input
: The camera receives one optically isolated trigger input. The interface consists of 2
wires
a.
Trigger In
(signal)
b.
User-Ground
(signal return). The trigger amplitude should be between 5V to24V. The interface
supports the Trigger frequency of up to 1MHZ at 50% duty cycle. The camera interface circuit
limits the input current to around 5ma. The design provides reverse polarity protection.
2.
Trigger modes:
are programmable for
a. Active-high
b. Active-low
c. Falling-edge
d. Rising-edge.