Technical Description &
Configuration Guide
Detailed
Configuration in Web
LigoWave
Page 42
admin
–
Enter new password (length: 4..30 characters)
– allows entering preferable „admin‟
account password. Maximal length of the user name cannot exceed 30 symbols. By default password
for „admin‟ account is „changeme‟. Admin account has full control of the LigoPTP 24 configuration
process.
Hide password(-s)
– Hides typed in password. Unchecking this option will display typed in password
in plaintext.
Pressing
Execute configuration
applies changes made to the corresponding section only for the local
side LigoPTP 24 FODU. If
Rollback on
is selected, configuration will be reverted in case of erroneous
configuration changes applied.
More detailed status controls are available in command prompt, which include additional user
management commands in Telnet/serial interface:
Command
Description
access login
<name>
<password>
Logs on as a user specified by <name> and <password>.
access logout
Logs current user out.
access set
<guest|admin>
<password> [plaintext]
Allows specifying a new password for a specific account
(admin or guest). „plaintext‟ option will save the password
in plaintext in configuration script without encrypting it (by
default saved passwords in configuration file are
encrypted).
access show
Shows user name and password of a user currently
logged on.
access list
Shows the list of usernames and passwords the current
account is able to manage (if logged on as admin, „guest‟
and „admin‟ account passwords will be seen).
Names Configuration
FODU name (Max length: 17 characters)
– allows entering preferable system name. It is
recommended to name the system after its geographic location. Maximum length of the user name
cannot exceed 17 symbols. Default name is
„LigoPTP (command line – system name <name>);