EM58 – HS58 - HM58 MODBUS TCP/IP
Singleturn resolution [113-114]
[112-113, Unsigned32, ro]
WARNING
These registers are active only if the bit 0
registers is set to “=0”; otherwise they are ignored and
the system uses the custom values (
Counts per revolution [101-102]
) to calculate the position information.
These registers are intended to show the number of physical distinguishable
steps per turn provided by the hardware (physical singleturn resolution).
If you want to set a custom resolution see the
registers.
Default = 8192
for EM58 series
262144
for HS58 series
65536
for HM58 series
Number of revolutions [115-116]
[114-115, Unsigned32, ro]
WARNING
These registers are active only if the bit 0
registers is set to “=0”; otherwise they are ignored and
the system uses the custom values (
Counts per revolution [101-102]
) to calculate the position information.
These registers are intended to show the number of physical distinguishable
turns provided by the hardware (number of physical revolutions).
The
Total hardware resolution
Singleturn resolution [113-114]
Number of revolutions [115-116]
If you want to set a custom number of turns see the
and
registers.
Default = 16384
for EM58 series
1
for HS58 series
16384
for HM58 series
MAN EM58_HS58_HM58 MT E 1.1.odt
Programming parameters
62 of 104