5.3 “NORMAL OPERATION“ mode
The DIL switch positions of the safety unit are:
By using the arrow buttons, this mode allows to enter the pages (display) of the
IFS-10-PM as follows:
Display 1: Frequencies (Hz)
Both input frequencies of sensor 1 and sensor 2 are
displayed with one decimal digit (see the
000
Operational Mode
parameter in the Main menu
of the safety unit “User's manual”).
The values are independent from the safety unit
scaling settings.
Display 2: Divergence (%)
It shows the divergence of both input frequencies
expressed in percentage. To set the reference
frequency, please refer to the
007 Div.
Calculation
parameter in the Main menu of the
safety unit.
The value depends on the scaling and divergence
parameter settings of the safety unit.
Display 3: Scaled Input 1
In this mode, the input frequency of the sensor 1 is
converted according to the parameters set in the
OPU menu of the safety unit and then shown on
the display. Refer also to the “6 - IFS-10-PM
parameters list” section on page 27
*
.
Display 4: Scaled Input 2
In this mode, the input frequency of the sensor 2 is
converted according to the parameters set in the
OPU menu of the safety unit and then shown on
the display. Refer also to the “6 - IFS-10-PM
parameters list” section on page 27
*
.
*
If the version of the safety device is older than 04A, these parameters are
available in the IFS-10. The maximum display value is ± 999 999 999.