RD4 CANopen®
3 Mechanical installation
WARNING
Installation and maintenance operations have to be carried out by qualified
personnel only, with power supply disconnected. Motor and shaft must be in
stop.
Figure 1 - RD4 unit – Overall dimensions
ROTADRIVE unit must be secured firmly only to the user's shaft using the
provided collar. ROTADRIVE unit is supplied with a screw insulation and an anti-
rotation pin; the anti-rotation pin (TE M5 screw) has to be inserted into the
screw insulation. This will provide to the unit both stability and the mobility
needed to absorb the mechanical tensions produced during operation. Do not
fasten firmly the anti-rotation pin to the flange or the fixed support on user's
side without using the screw insulation! If this occurs, the mechanical tensions
would be transmitted completely to the motor shaft and this would lead to
bearings damages and mechanical breakdowns!
MAN RD4 CB E 1.5
Mechanical installation
14 of 72