RD4 CANopen®
Slave
Master (Boot-up)
COB-ID
Cmd
700+ID
00
NOTE
function.
1014-00 COB-ID EMCY
[Unsigned32, rw]
This object defines the COB-ID used to send emergency messages (EMCY).
When the power is turned on, this object always contains the default value.
For a complete list of the emergency messages refer to section “8.3 Emergency
messages” on page 67.
Default = 80h+Node ID
1015-00 Inhibit Time Emergency
[Unsigned16, rw]
Inhibit time of emergency messages (EMCY), i.e. minimum interval between
subsequent emergency messages expressed in multiples of 100 µs.
Default = 0
1018 Identity Object
01
Vendor Id
[Unsigned32, ro]
02
Product code
[Unsigned32, ro]
03
Revision number
[Unsigned32, ro]
04
Serial number
[Unsigned32, ro]
MAN RD4 CB E 1.5
Programming parameters
49 of 72