RD4 CANopen®
bit 8: 0080h
Overtemperature
The internal temperature of the
device as sensed by a probe is
exceeding maximum ratings (see
).
bit 9
Not used
bit 10: 0400h
Undervoltage
The power supply voltage is under
minimum ratings.
bit 11: 0800h
CAN Life guard error
Error in the “Node guarding
protocol”. For further information
see section “8.4 Node guarding
protocol” on page 68.
bit 12…15
Not used
To reset a faulty condition use
bit. Setting this bit to “1” causes the
normal work status of the device to be restored. This command is used to reset
an alarm condition of the Slave but only if the faulty condition has ceased.
Using SDO messages you can read further information about the alarm in the
index
Please note that should the alarm be caused by wrong object values (see
), normal work status can be restored only after having
alarm cannot be reset.
NOTE
function.
Should the power be turned off or
Reset node
or
Reset communication
commands be sent all data not saved will be lost!
MAN RD4 CB E 1.5
Programming parameters
66 of 72