RD4 CANopen®
3341-00 Starting Torque current
[Unsigned32, rw]
This object defines the maximum current supplied to the motor only when it
starts its movement and for the maximum time set in the object
. Parameter is expressed in mA (milliamperes). Maximum
value is 7000.
Default = 7000
3342-00 Gear ratio
[Unsigned32, ro]
It displays the gear ratio of the reduction gear installed between the motor and
the encoder shaft. This is a read-only parameter.
Default = 32 for RD4-...-T32-... model
Default = 48 for RD4-...-T48-... model
3343-00 Positive absolute limit switch
value (maximum positive limit) calculated
according to values set in parameters
sub 1
Positive delta
. When the maximum forward limit is reached, a signalling
status bit.
Positive
delta
.
Value is expressed in encoder pulses.
3344-00 Negative absolute limit switch
value (maximum negative limit) calculated
according to values set in parameters
sub 2
Negative delta
. When the maximum backward limit is reached, a
signalling is activated through the
status bit.
Negative
delta
.
Value is expressed in encoder pulses.
NOTE
function.
Should the power be turned off or
Reset node
or
Reset communication
commands be sent all data not saved will be lost!
MAN RD4 CB E 1.5
Programming parameters