SFA-5000 • SFA-10000 DeviceNet
4.6 Setting the baud rate: DIP A
WARNING
Power supply must be turned off before performing this operation!
The baud rate must be set using
DIP A
dip-switches:
Switch off the unit and set the binary value of the transmission rate considering
that: ON=1, OFF=0.
bit
1
LSB
2
MSB
3
4
2
0
2
1
OFF
OFF
Table of the available baud rate values:
Binary value
Baud rate
00
125 Kbit/s
01
250 Kbit/s
10
500 Kbit/s (default)
NOTE
Bits 3 and 4 must be always set to OFF.
EXAMPLE
Set the baud rate to 250 Kbit/s:
01
(binary value, see the table above)
bit
1
2
3
4
ON
OFF
OFF
OFF
Set the baud rate to 500 Kbit/s:
10
(binary value, see the table above)
bit
1
2
3
4
OFF
ON
OFF
OFF
MAN SFA_5000_10000_FD E 1.0.odt
Electrical connections
23 of 88