SFA-5000 • SFA-10000 DeviceNet
6.4.4 Message data transfer
These messages are meant to set, read, save or restore configuration parameters.
Data transfer request:
Byte
bit7
bit6 bit5 bit4 bit3 bit2 bit1
bit0
0
F=0
0
Master MAC-ID
1
R/R=0
Service Code
2
Class ID
3
Instance ID
4
Attribute ID
5…7
Data byte
Data transfer response:
Byte
bit7
bit6 bit5 bit4 bit3 bit2 bit1
bit0
0
F=0
0
Master MAC-ID
1
R/R=1
Service Code
2…7
Data byte
Service code, Class ID, Instance ID and Attribute ID are meant to set the type
and content of data bytes. They must be specified according to the “Object
dictionary” (see the “6.5 Object dictionary“ section on page 57).
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
56 of 88