SFA-5000 • SFA-10000 DeviceNet
This attribute is intended to show the number of physical distinguishable steps
per each revolution provided by the hardware (physical singleturn resolution).
If you want to set a custom singleturn resolution see the
Default = 8,192
9 Physical number of revolutions
WARNING
This attribute is active only if the
”=0”; otherwise it is ignored and the system uses the custom values (
) to calculate the position
information.
This attribute is intended to show the number of physical revolutions provided
by the hardware (number of physical revolutions).
The
Total hardware resolution
8 Physical resolution/revolution
9 Physical number of revolutions
If you want to set a custom number of revolutions see the
and
Default = 4,096
10 Alarms
An alarm is set when a bit indicating a fault is set to true (high). See the
values.
Default = 0 (min. = 0, max. = 32 767)
11 Supported alarms
This attribute contains information on the supported alarms.
Bits 0 … 11 Reserved
Bit 12
Flash memory error
Internal error, it cannot be restored.
Bit 13
Machine data not
valid
One or more parameters are not valid, set
proper values to restore normal work
condition.
Bit 14
Bus off
This bit is intended to warn that the
communication in the bus network has
broken (cable disconnected? Voltage drop?
...).
Default = 0 (min. = 0, max. = 32 767)
MAN SFA_5000_10000_FD E 1.0.odt Quick reference (using RSNetWorx)45 of 88