SFA-5000 • SFA-10000 DeviceNet
17 Data Tx in COS/Cyclic mode
This parameter is meant to set which input data is sent when the
(COS) /
mode connection is enabled.
Allowed values:
Position value (0, default value)
Position value + velocity (1)
Default = 0 (min. = 0, max. = 1)
18 Alarm flags
It shows whether a fault occurred and an alarm has been activated, see the
attribute.
NO (0)
No active alarm
YES (1)
Active alarms
Default = 0 (min. = 0, max. = 1)
19 Delta for COS
(COS) mode connection is enabled, this parameter
sets the minimum gap between two I/O messages. Values too low could cause
the Bus network to saturate.
Default = 5 (min. = 0, max. = 262 143)
20 Auto-save parameters
NO (0): New parameters are not saved on EPROM automatically. To save new
values Class Instance Editor must be used (default value; see the “5.4
Saving the parameters with RSNetWorx” section on page 33).
YES (1): When a new parameter is set, the encoder waits 5 seconds and then
saves automatically all the new values on EPROM, but only if the
received value has been changed.
Default = 0 (min. = 0, max. = 1)
MAN SFA_5000_10000_FD E 1.0.odt Quick reference (using RSNetWorx)47 of 88