SFA-5000 • SFA-10000 DeviceNet
6.5.2 Class 03h: DeviceNet Object
This DeviceNet Object is meant to provide the configuration and status of the
physical node connected to the DeviceNet network.
Supported
Service code:
0Eh = Get_Attribute_Single: used to read connection class attribute value.
10h = Set_Attribute_Single: used to write connection class attribute value.
Supported
Instance:
01h = Explicit Message
03-01-01 Node Address
[USINT, ro]
This attribute contains the MAC-ID of the device.
To set the node address see the “4.7 Setting the node address: DIP B” section on
page 24.
03-01-02 Baud rate
[USINT, ro]
This attribute shows the set baud rate.
Binary value
Baud rate
00
125 Kbit/s
01
250 Kbit/s
10
500 Kbit/s (default)
To set the baud rate see the “4.6 Setting the baud rate: DIP A” section on page
23.
03-01-03 Bus-off interrupt
[BOOL, ro]
This attribute sets how the device has to act after a bus-off event.
00: when a bus-off event occurs, device resets and hold the bus-off (reset)
status.
01: when a bus-off event occurs, device resets and then tries to get the
previous communication status.
Default = 01h
03-01-04 Bus-off counter
[USINT, ro]
This attribute shows the number of triggered bus-off events.
Default = 00h
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
61 of 88