SFA-5000 • SFA-10000 DeviceNet
23-01-11 Total measuring range
attributes that are
consistent with the physical values.
WARNING
Every time you enable the scaling function and/or change the scaling values (see
the
23-01-10 Resolution per revolution
attributes) then you are required to set a new preset value (see the
attribute) and finally save the new parameters (execute the
“Save parameters” function, see “7.1.4 Saving the parameters“ in the “7.1 Read
and set parameters“ section on page 81).
23-01-10 Resolution per revolution
[UDINT, rw]
WARNING
This attribute is active only if the
23-01-0E Scaling function control
is set to ”=01”; otherwise it is ignored and the system uses the physical values
(
23-01-2A Hardware counts per revolution
) to calculate the position information.
This attribute sets a custom number of distinguishable steps per revolution
(custom singleturn resolution).
To avoid counting errors, check that
23-01-2A Hardware counts per revolution
= integer value.
23-01-10 Resolution per revolution
You are allowed to set whatever integer value less than or equal to the
maximum number of physical steps per revolution
(see the hardware counts
per revolution in the encoder identification label and the
attribute).
Default = 0000 2000h (8,192 cpr)
WARNING
When you set a new value next to the
23-01-10 Resolution per revolution
attribute, please always check also the
23-01-11 Total measuring range
attribute value and be sure that the resulting number of revolutions complies
with the
Hardware number of revolutions
of the device (4,096 revolutions,
23-01-2B Hardware number of turns
attribute).
Let's suppose that the encoder is programmed as follows:
23-01-10 Resolution per revolution
: 8,192 cpr
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
69 of 88