SFA-5000 • SFA-10000 DeviceNet
7.1.5 Closing the Master/Slave connection
Master
Encoder
CAN-ID
5 Data byte
406+(ID<<3)
Ms
SC
Cl
Ins
AC
00
4C
03
01
01
Encoder
Master
CAN-ID
3 Data byte
403+(ID<<3)
Ms
SC
Err
00
CC
00
7.2 Setting the Cyclic mode without velocity
7.2.1 P2P Master/Slave connection
Master
Encoder (request)
CAN-ID
6 Data byte
406+(ID<<3)
Ms
SC
Cl
Ins
AC
Ms
00
4B
03
01
61
00
Encoder
Master (response)
CAN-ID
3 Data byte
403+(ID<<3)
Ms
SC
Err
00
CB
00
05-Inst-09 Expected packet rate
for Cyclic mode
(milliseconds)
Master
Encoder
CAN-ID
7 Data byte
404+(ID<<3)
Ms
SC
Cl
Ins
At
Ctime
00
10
05
04
09 Low
Hi
Encoder
Master
CAN-ID
3 Data byte
403+(ID<<3)
Ms
SC
Err
00
90
00
MAN SFA_5000_10000_FD E 1.0.odt
Setup
82 of 88