5.1.1- Keep trolley locked, pull or push the door by hand, make sure the trolley connects
with the chain connection device. (until you hear it block).
5.1.2- Turn on the power, the courtesy light is on for several seconds.
Meanwhile, LED display will show numbers from "
9
" to "
1
". Then the operator turns to
standby situation.
5.1.3- At last, it displays "
I I
" or "
-
".
5.2.1- Press and hold button
SET
until display shows "
1
".
5.2.2- Press and hold button
UP
.
5.2.3- When the door has reached the open position, press button
SET
. It displays "
2
".
5.2.4- Then press and hold button
DOWN
,When the door has reached the closed position,
press the button
SET
.
Note: In closed position, the door shouldn’t make too much force/pressure
against to floor .
Lock
5.1 Preparing
5.2 Setting open and close positions
UP
DOWN
SET
CODE
5. Programming the operator
LIKE IT
43
During programming of the limit switch in the closing position, the engine track shall
NOT
show any
curving (not be bowed) (fig. 2) , it shall be completely straight without any deformation (fig. 1).
If the floor where the sectional door is installed has a slope (inclination between the two edges of the floor
where the bottom rubber seals the door), the difference between the highest and lowest end of the floor
can never be compensated with the motor force, but with the panel cuttedf with the same slope. If the
panel is not cutted, the limit switch programming should be done in the highest position of the floor.
EN
Summary of Contents for PRO600
Page 5: ...1x 1011d 1x 1023d 1 2 3 4 5 6 LIKE IT 4...
Page 6: ...1x 1030d 9 10 11 7 8 LIKE IT 5...
Page 7: ...1x 1000d 4x 1006d 2x 1016d 4x 1028d 1x 1032d 1x 1012d 12 13 14 15 LIKE IT 6...
Page 9: ...L 2 1x 1019d 3x 1008d 45 mm 6x 1004d 1x 1017d 19 20 21 LIKE IT 8...
Page 11: ...1x 1001d 1x 1009d 1x 1009d 1x 1001d 1x 1022d 25 26 27 LIKE IT 10...