C. Position the cursor beside ZONE DISPLAY, select ON/OFF by
using [LEFT/RIGHT] key.
ON: masked zones are displayed.
OFF: masked zones are disabled.
D. Position the cursor beside RET and press [SET] key and return to
Setup Menu 02.
IR CUT REMOVE CONTROL
AUTO
1
17
1. Position the cursor beside IR CUT REMOVE and select AUTO by using
[LEFT/RIGHT] key.
2. Press [SET] key to display the ICR AUTO
SETTING menu.
IN LUX LEVEL: 0~20
(about 20lux ~ 35lux)
OUT LUX LEVEL: 0~20
(about 3lux ~ 15lux)
ICR AUTO SETTING
IN LUX LEVEL
OUT LUX LEVEL
DELAY TIME
RET
10
14
02 sec
When light level is higher than IN LUX LEVEL, IR Cut Filter switches ON
automatically to produce color image.
When light level drops below OUT LUX LEVEL, IR Cut Filter switches OFF
automatically to produce B/W image.
Under B/W mode, sensitivity is increased to 0.01LUX and is sensitive to IR
illuminator.
NOTE
Setting Expose mode, AGC gain, BLC, Flickerless functions and iris level of
Auto Iris Lens all will affect the reaction of the ICR auto switch so the IN or OUT
LUX LEVEL have to be re-set.
REMARK
3. Position the cursor beside DELAY TIME, select delay time by using [
LEFT/RIGHT] key.
DELAY TIME: 02 ~ 10 sec.